Mostrar el registro sencillo del ítem

dc.contributor.advisorPérez Mallada, Néstor
dc.contributor.authorTenorio Mujica, Antonia
dc.contributor.otherUniversidad Pontificia Comillas, Escuela Universiaria de Enfermería Y Fisioterapiaes_ES
dc.date.accessioned2022-05-13T09:40:56Z
dc.date.available2022-05-13T09:40:56Z
dc.date.issued2021
dc.identifier.urihttp://hdl.handle.net/11531/68156
dc.descriptionTitulación::Postgrado::Máster Universitario en Biomecánica y Fisioterapia Deportivaes_ES
dc.description.abstractIntroducción: El hombro es el complejo articular más móvil del ser humano. La articulación glenohumeral (GH) es una articulación sinovial multiaxial, permitiendo una gran amplitud de movimiento. La estabilización inadecuada da como resultado una traslación excesiva de la cabeza humeral, lo que puede provocar subluxación o dislocación sintomática. La evaluación de la movilidad es una parte importante en los exámenes físicos y clínicos. Es necesario disponer de herramientas fiables para evaluar de forma precisa y objetiva el estado funcional de una articulación. En biomecánica, el análisis de electromiografía (EMGs) proporciona información importante sobre la actividad muscular el cual nos informa sobre fatiga y velocidad muscular que puede ser útil para optimizar el rendimiento. Otro tipo de herramienta es el dinamómetro, el cual se considera para evaluar la fuerza muscular, además se utiliza para controlar el progreso durante la rehabilitación. Destacan ambas por su precisión y objetividad confiables. El reconocimiento del desequilibrio o déficit muscular podría ser una variable clave para orientar las sesiones de entrenamiento y evitar lesiones posteriores. Objetivos: Obtener datos normativos dinamométricos y electromiográficos de la musculatura de abducción (ABD) de hombro. Materiales y métodos: Estudio observacional descriptivo de diseño transversal. se reclutaron 16 voluntarios, hombres y mujeres sin patología previa, entre 18 y 65 años. Resultados: Los resultados se muestran en media y desviación estándar (DS). Se obtuvo un valor de 40.75 ± 15.32 Nm, 37.73 ± 13.53 Nm, 33.78 ± 11.82 Nm para los 60°, 90° y a los 120° de ABD de hombro respectivamente. La actividad muscular, en RMS, a los 60° de ABD de hombro para el pectoral mayor (PMa) 0.048± 0.03 mV, deltoides anterior (DA) 0,768± 0.17 mV, deltoides medio (DMe) 0,580 ± 0.18 mV, deltoides posterior (DP) 0,509 ± 0.25 mV, redondo mayor (RM) 0,118 ± 0.08 mV. A los 90° de ABD PMa 0.051± 0.04 mV, DA 0,801± 0.14 mV, DMe 0,565 ± 0.15 mV, DP 0,495 ± 0.20 mV, RMa 0,143 ± 0.07 mV. A los 120° de ABD para PMa fue 0,110± 0.02 mV, DA 0,802 ± 0.12 mV, DMe 0,545 ± 0.16 mV, DP 0,452 ± 0.17 mV, RMa 0,167 ± 0.02 mV. Discusión y Conclusiones: Se han extraído valores normativos de las variables de fuerza y actividad muscular para dar respuesta a distintos ámbitos tanto en rehabilitación como de forma preventiva.es_ES
dc.description.abstractIntroduction: The shoulder is the most mobile joint complex in humans. The glenohumeral joint (GH) is a multiaxial synovial joint, allowing a great range of motion. Inadequate stabilization results in excessive translation of the humeral head, which can lead to symptomatic subluxation or dislocation. Evaluation of mobility is an important part of physical and clinical examinations. Reliable tools are required to assess the functional status of a joint accurately and objectively. In biomechanics, electromyography (EMGs) analysis provides important information on muscle activity which informs us about fatigue and muscle speed that can be useful to optimize performance. Another type of tool is the dynamometer, which is considered to evaluate muscle strength, it is also used to monitor progress during rehabilitation. Both stand out for their dependable precision and objectivity. Recognition of muscle imbalance or deficit could be a key variable in guiding training sessions and avoiding subsequent injuries. Objectives: Obtain normative dynamometric and electromyographic data of the shoulder abduction (ABD) muscles. Materials and methods: Descriptive observational study of cross-sectional design. 16 volunteers were recruited, men and women without previous pathology, between 18 and 65 years old. Results: The results are shown in mean and standard deviation (SD). A value of 40.75 ± 15.32 Nm, 37.73 ± 13.53 Nm, 33.78 ± 11.82 Nm was obtained for the 60 °, 90 ° and 120 ° of shoulder ABD, respectively. Muscle activity, in RMS, at 60 ° ABD of shoulder for pectoralis major (PMa) 0.048 ± 0.03 mV, anterior deltoid (AD) 0.768 ± 0.17 mV, middle deltoid (MD) 0.580 ± 0.18 mV, posterior deltoid (PD) 0.509 ± 0.25 mV, teres major (TMa) 0.118 ± 0.08 mV. At 90 ° ABD PMa 0.051 ± 0.04 mV, AD 0.801 ± 0.14 mV, MD 0.565 ± 0.15 mV, PD 0.495 ± 0.20 mV, TMa 0.143 ± 0.07 mV. At 120 ° ABD for PMa was 0.110 ± 0.02 mV, AD 0.802 ± 0.12 mV, MD 0.545 ± 0.16 mV, PD 0.452 ± 0.17 mV, TMa 0.167 ± 0.02 mV. Discussion and Conclusions: Normative values have been extracted from the variables of muscle strength and activity to respond to different areas both in rehabilitation and preventively.es_ES
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoeses_ES
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subjectUNESCO::32 Medicina::3213 Cirugía::321311 Fisioterapiaes_ES
dc.subjectUNESCO::24 Ciencias de la vida::2402 Antropología física::240203 Antropometría y antropología forensees_ES
dc.subjectUNESCO::24 Ciencias de la vida::2411 Fisiología humana::241110 Fisiología del músculoes_ES
dc.subjectUNESCO::24 Ciencias de la vida::2406 Biofísica::240604 Biomecánicaes_ES
dc.titleValores normativos dinamométricos y electromiográficos de la musculatura de abducción de hombroes_ES
dc.typeinfo:eu-repo/semantics/masterThesises_ES
dc.rights.accessRightsinfo:eu-repo/semantics/closedAccesses_ES
dc.keywordsBiomecánica, Hombro, Abducción, Electromiografía, Dinamometríaes_ES
dc.keywordsBiomechanics, Shoulder, Abduction, Electromyography, Dynamometryes_ES


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivs 3.0 United States
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivs 3.0 United States