Detailed analysis and experimental results of the control system of a UPFC

Thumbnail
Ver/
IIT-03-127R.pdf (402.6Kb)
IIT-03-127R_preview (2.822Kb)
IIT-03-127R_preview.pdf (2.822Kb)
Fecha
2003-03-01
Autor
García González, Pablo
García Cerrada, Aurelio
Estado
info:eu-repo/semantics/publishedVersion
Metadatos
Mostrar el registro completo del ítem
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Resumen
This paper explains the decoupled control of the power flow through a transmission line using a PWM based Unified Power Flow Controler (UPFC). The dynamic model of the UPFC has been developed using the space-vector representation of the instantaneous three-phase variables. The Park´s transformation and the reference frame selected reduce the control of the real and reactive-power flows to the control of the d- and q-axis currents, respectively. The proposed control scheme produces fast and decoupled response of the real and the reactive-power flow through a transmission line. It also achieves tight control of the d.c.-link capacitor voltage, thanks to the careful coordination between the control of the series and shunt compensators of the UPFX. A 15 kVA prototype with 750 Hz switching frequency has been built to illustrate the main contributions. Experiemental results agree closely with the theoretical analysis.
 
This paper explains the decoupled control of the power flow through a transmission line using a PWM based Unified Power Flow Controler (UPFC). The dynamic model of the UPFC has been developed using the space-vector representation of the instantaneous three-phase variables. The Park´s transformation and the reference frame selected reduce the control of the real and reactive-power flows to the control of the d- and q-axis currents, respectively. The proposed control scheme produces fast and decoupled response of the real and the reactive-power flow through a transmission line. It also achieves tight control of the d.c.-link capacitor voltage, thanks to the careful coordination between the control of the series and shunt compensators of the UPFX. A 15 kVA prototype with 750 Hz switching frequency has been built to illustrate the main contributions. Experiemental results agree closely with the theoretical analysis.
 
URI
https://doi.org/10.1049/ip-gtd:20030026
Detailed analysis and experimental results of the control system of a UPFC
Tipo de Actividad
Artículos en revistas
ISSN
1350-2360
Materias/ categorías / ODS
Instituto de Investigación Tecnológica (IIT)
Palabras Clave
PWM invertors; compensation; load flow control; power transmission control; power transmission lines; reactive power control
PWM invertors; compensation; load flow control; power transmission control; power transmission lines; reactive power control
Colecciones
  • Artículos

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias
 

 

Búsqueda semántica (CKH Explorer)


Listar

Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipoEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipo

Mi cuenta

AccederRegistro

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias