Mostrar el registro sencillo del ítem

dc.contributor.authorMartínez Vílchez, Oibares-ES
dc.contributor.authorRonda, Silviaes-ES
dc.contributor.authorOliver, Claraes-ES
dc.contributor.authorMárquez, Patriciaes-ES
dc.contributor.authorMiranda, José Migueles-ES
dc.date.accessioned2023-07-20T06:56:23Z
dc.date.available2023-07-20T06:56:23Z
dc.date.issued2021-06-08es_ES
dc.identifier.issn2327-588Xes_ES
dc.identifier.urihttps://doi.org/10.4236/jpee.2021.96002es_ES
dc.descriptionArtículos en revistases_ES
dc.description.abstract.es-ES
dc.description.abstractThis paper is devoted to the study of the most suitable protocols needed to verify the lightning protection and ground resistance quality in a large-scale scientific facility located on a site with high risk of lightning strikes. We illustrate this work by reviewing a case study: the largest telescopes of the Northern Hemisphere Cherenkov Telescope Array, CTA-N. This array hosts sensitive and high-speed optoelectronics instrumentation and sits on a clear, free from obstacle terrain at around 2400 m above sea level. The site offers a top-quality sky but also features challenging conditions for a lightning protection system: the terrain is volcanic and has electrical resistivities well above 1 kOhm·m. In addition, the environment often exhibits humidities well below 5%, and strong winds pose challenging conditions. On the other hand, the high complexity of a Cherenkov telescope structure does not allow a straightforward application of lightning protection standards. We describe here how the risk assessment of direct strike impacts was made and how contact voltages and ground system were both tested. Finite Element Simulation (COMSOL Multiphysics) has been used to estimate the current flowing through the parts of the earthing system designed for the telescopes in the case of a direct strike impact. This work is intended to provide assistance to scientists and managers involved in the construction of scientific installations, particularly those in charge of defining verifiable reliability and safety requirements for lightning protection.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightsCreative Commons Reconocimiento-NoComercial-SinObraDerivada Españaes_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/es_ES
dc.sourceRevista: Journal of Power and Energy Engineering, Periodo: 1, Volumen: 9, Número: , Página inicial: 12, Página final: 28es_ES
dc.titleVerification Protocols for the Lightning Protection of a Large Scale Scientific Instrument in Harsh Environments: A Case Studyes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywords.es-ES
dc.keywordsLightning Protection, Earth Resistance, FEM, COMSOLen-GB


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

  • Artículos
    Artículos de revista, capítulos de libro y contribuciones en congresos publicadas.

Mostrar el registro sencillo del ítem

Creative Commons Reconocimiento-NoComercial-SinObraDerivada España
Excepto si se señala otra cosa, la licencia del ítem se describe como Creative Commons Reconocimiento-NoComercial-SinObraDerivada España