Mostrar el registro sencillo del ítem
Análisis técnico-económico de la tecnología eólica marina y comparación frente a la generación solar
dc.contributor.advisor | Talavera Martín, Juan Antonio | es-ES |
dc.contributor.author | Chacón García, Luis | es-ES |
dc.contributor.other | Universidad Pontificia Comillas, Escuela Técnica Superior de Ingeniería (ICAI) | es_ES |
dc.date.accessioned | 2024-02-01T10:33:26Z | |
dc.date.available | es_ES | |
dc.date.issued | 2024 | es_ES |
dc.identifier.uri | http://hdl.handle.net/11531/86660 | |
dc.description | Máster Universitario en Ingeniería Industrial | es_ES |
dc.description.abstract | Este proyecto tiene como objetivo evaluar técnica y económicamente una instalación eólica marina y compararla con una planta fotovoltaica de igual potencia. Para ello, se realiza un análisis detallado del contexto político y del mercado eléctrico en España y Europa, abordando el impacto de eventos globales como la pandemia de COVID-19 y el conflicto entre Rusia y Ucrania. También se examinan las políticas energéticas de la Unión Europea orientadas hacia la transición energética. El análisis técnico de la instalación eólica marina incluye la selección del emplazamiento en España, considerando la normativa vigente y las características del entorno marino. Se evalúan aspectos como la capacidad instalada, el diseño del parque eólico y la infraestructura necesaria para la conexión a la red eléctrica. Además, se realiza un estudio de mercado para identificar los componentes clave, como turbinas y convertidores, con el fin de seleccionar los más eficientes y rentables, estableciendo una estimación precisa del capital inicial (CAPEX). El software Bladed se emplea para simular y dimensionar la planta, centrándose en las cargas últimas que afectan a la torre del aerogenerador, para diseñar una estructura capaz de soportarlas durante 25 años. Posteriormente, se desarrolla un análisis financiero para evaluar la rentabilidad del proyecto, considerando costos operativos (OPEX), amortización y proyecciones de producción y precios de energía. Este análisis se compara con una instalación fotovoltaica de igual potencia, utilizando un modelo financiero para determinar la viabilidad económica de ambos proyectos mediante indicadores como la Tasa Interna de Retorno (TIR) y el Valor Actual Neto (VAN). Finalmente, se presentan los resultados y conclusiones, destacando los parámetros financieros que enriquecen el estudio. | es-ES |
dc.description.abstract | The aim of this project is to technically and economically evaluate an offshore wind farm and compare it with a photovoltaic plant of equal power. To this end, a detailed analysis of the political and electricity market context in Spain and Europe is carried out, addressing the impact of global events such as the COVID-19 pandemic and the conflict between Russia and Ukraine. It also examines the European Union's energy policies oriented towards the energy transition. The technical analysis of the offshore wind installation includes the selection of the site in Spain, considering the current regulations and the characteristics of the marine environment. Aspects such as the installed capacity, the design of the wind farm and the infrastructure necessary for connection to the electricity grid are evaluated. In addition, a market study is carried out to identify the key components, such as turbines and converters, in order to select the most efficient and profitable ones, establishing an accurate estimate of the initial capital (CAPEX). Bladed software is used to simulate and size the plant, focusing on the ultimate loads affecting the wind turbine tower to design a structure capable of supporting them for 25 years. Subsequently, a financial analysis is developed to evaluate the profitability of the project, considering operational costs (OPEX), amortisation and production projections and energy prices. This analysis is compared with a photovoltaic installation of equal power, using a financial model to determine the economic viability of both projects through indicators such as the Internal Rate of Return (IRR) and the Net Present Value (NPV). Finally, the results and conclusions are presented, highlighting the financial parameters that enrich the study. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | en-GB | es_ES |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 United States | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | es_ES |
dc.subject.other | H62-electrotecnica (MII-E) | es_ES |
dc.title | Análisis técnico-económico de la tecnología eólica marina y comparación frente a la generación solar | es_ES |
dc.type | info:eu-repo/semantics/masterThesis | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
dc.keywords | Eólica marina, Fotovoltaica, Análisis técnico-económico, Estado último de cargas, Energía renovable, Simulación de producción | es-ES |
dc.keywords | Offshore wind power, Photovoltaics, Technical-economic analysis, Ultimate state of charge, Renewable energy, Production simulation | en-GB |