Mostrar el registro sencillo del ítem

dc.contributor.authorJordehi, Ahmad Rezaeees-ES
dc.contributor.authorMansouri, Seyedamires-ES
dc.contributor.authorTostado Véliz, Marcoses-ES
dc.contributor.authorAhmarinejad, Amires-ES
dc.contributor.authorJurado Melguizo, Franciscoes-ES
dc.date.accessioned2024-02-23T13:14:56Z
dc.date.available2024-02-23T13:14:56Z
dc.date.issued2024-01-02es_ES
dc.identifier.issn0360-3199es_ES
dc.identifier.urihttps:doi.org10.1016j.ijhydene.2023.07.277es_ES
dc.descriptionArtículos en revistases_ES
dc.description.abstractes-ES
dc.description.abstractExtreme events such as floods, hurricanes, earthquakes, and wildfires pose significant threats to the uninterrupted supply of electricity to consumers, as they can cause the failure of numerous power system components. The resilience of a power system is defined by its ability to withstand extreme events and continue meeting demand. While the placement of multi-carrier microgrids (MGs) in power systems can impact resilience, the literature lacks research on resilience-oriented placement. This paper aims to address this gap by proposing a resilience-oriented placement strategy for multi-carrier MGs, utilizing switchable transmission lines to enhance the resilience of power systems. The study focuses on a heat-power-hydrogen MG that obtains gas from a gas network, exchanges power with the main power system, and incorporates combined heat and power (CHP), electrolyzer, and thermal storage. The developed model employs a stochastic mixed-integer linear programming (MILP) approach, ensuring the attainment of the global optimum. Resilience is evaluated using the metric of expected load not supplied (ELNS). The results demonstrate that when the bus connected to the MG is isolated, the MG generates electricity through its CHP unit to meet local demand, reducing the total demand shed in the power system and improving system resilience. Specifically, the MG reduces ELNS from 4955.48 MWh to 2356.64 MWh, indicating a remarkable 52 improvement in ELNS. Furthermore, the study shows that transmission line switching further decreases ELNS from 2356.64 MWh to 848.68 MWh. Several experiments are conducted to analyze the sensitivity of power system resilience to the number of MGs, the MG-power system exchange limit, and the limit on gas import from the gas network.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: International Journal of Hydrogen Energy, Periodo: 1, Volumen: online, Número: Part B, Página inicial: 175, Página final: 185es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleResilience-oriented placement of multi-carrier microgrids in power systems with switchable transmission lineses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsPower system resilience; Microgrids; Transmission switching; Heat-power-hydrogen microgridsen-GB