dc.contributor.authorJordehi, Ahmad Rezaeees-ES
dc.contributor.authorMansouri, Seyedamires-ES
dc.contributor.authorTostado Véliz, Marcoses-ES
dc.contributor.authorIqbal, Atifes-ES
dc.contributor.authorMarzband, Mousaes-ES
dc.contributor.authorJurado Melguizo, Franciscoes-ES
dc.date.accessioned2024-02-23T13:15:09Z
dc.date.available2024-02-23T13:15:09Z
dc.date.issued2024-01-02es_ES
dc.identifier.issn0360-3199es_ES
dc.identifier.urihttps:doi.org10.1016j.ijhydene.2023.07.205es_ES
dc.descriptionArtículos en revistases_ES
dc.description.abstractes-ES
dc.description.abstractIn recent decades, climate change has severely increased the concerns over the resilience of power systems. Extreme events may lead to the failure of a large number of system components and result in interruption of supply to lots of consumers. In this research, the main objective is to use and assess the potential of large industrial energy hubs (EHs) in resilience improvement of power systems. Mobile energy storage and demand response programs are also used to decrease involuntary demand shed in system and enhance system resilience. A stochastic mixed-integer linear programming model is developed considering the uncertainties in damaged transmission lines, hurricane time and repair time. Case study is a modified IEEE 24-bus power system with EHs. The studied EH receives gas from a gas network, exchanges power with power system, includes combined heat and power (CHP), generator, electrolyzer, boiler, thermal storage and hydrogen storage system and feeds electric, heat and hydrogen demands. Expected load not supplied (ELNS) is used as resilience metric. The results approve significant impact of EH in improvement of power system resilience. In scenarios in which the bus connected to EH is isolated, EH supplies the power system demand located at that bus and thereby improves system resilience; on the other hand, in other scenarios, EH typically behaves as an electricity consumer of power system. According to the results, mobile energy storage causes a 2.4 improvement in ELNS. The results also show that demand response program improves ELNS by 7.1.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: International Journal of Hydrogen Energy, Periodo: 1, Volumen: online, Número: Part B, Página inicial: 77, Página final: 91es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleIndustrial energy hubs with electric, thermal and hydrogen demands for resilience enhancement of mobile storage-integrated power systemses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsPower system resilience; Energy hub; Hydrogen; Mobile storage; Heat & power & hydrogen; Demand responseen-GB