• English
    • español
  • English 
    • English
    • español
  • Login
View Item 
  •   Home
  • 2.- Investigación
  • Artículos
  • View Item
  •   Home
  • 2.- Investigación
  • Artículos
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Confronting the threat: analysis of the impact of MaDIoT attacks in two power system models

Thumbnail
View/Open
%20analysis%20of%20the%20impact%20of%20MaDIoT%20attacks%20in%20two%20power%20system%20models (407.3Kb)
Date
2023-12-01
Author
Rodríguez Pérez, Néstor
Matanza Domingo, Javier
Sigrist, Lukas
Rueda Torres, José Luis
López López, Gregorio
Estado
info:eu-repo/semantics/publishedVersion
Metadata
Show full item record
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Abstract
 
 
The increasing penetration of Internet of Things (IoT) devices at the consumer level of power systems also increases the surface of attack for the so-called Manipulation of Demand through IoT (MaDIoT) attacks. This paper provides a comparison of the impact that MaDIoT attacks could have on power systems with different characteristics, such as the IEEE 39-Bus (New England) and the PST-16 system (simplified European model), by assuming that the attacker does not have advanced knowledge of the grid. The results for the IEEE 39-Bus system expand and complement the results obtained by previous work. The simulation results show that these systems present significant differences between them with respect to the success probability of an attack, being in general much higher for the IEEE 39-Bus system. In the PST-16 system, the required number of bots to obtain a certain success probability varies depending on the area attacked. However, a high probability of success does not necessarily mean a high impact on the system. This paper shows that the response to the high-impact MaDIoT attacks of the two models considered is very different as the initial impact of the attack on the system also differs, mainly affecting rotor angles in the PST-16 system, and the frequency in the IEEE 39-Bus.
 
URI
https:doi.org10.3390en16237732
Confronting the threat: analysis of the impact of MaDIoT attacks in two power system models
Tipo de Actividad
Artículos en revistas
ISSN
1996-1073
Materias/ categorías / ODS
Instituto de Investigación Tecnológica (IIT)
Palabras Clave

cyberattack; power system dynamics; MaDIoT; load altering attacks; power system stability
Collections
  • Artículos

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback
 

 

Búsqueda semántica (CKH Explorer)


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_typeThis CollectionBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_type

My Account

LoginRegister

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback