Mostrar el registro sencillo del ítem

dc.contributor.authorJankovic, Njegoses-ES
dc.contributor.authorRoldan Perez, Javieres-ES
dc.contributor.authorProdanovic, Milanes-ES
dc.contributor.authorSuul, Jon Arees-ES
dc.contributor.authorD'Arco, Salvatorees-ES
dc.contributor.authorRouco Rodríguez, Luises-ES
dc.date.accessioned2024-02-23T13:31:11Z
dc.date.available2024-02-23T13:31:11Z
dc.date.issued2023-07-01es_ES
dc.identifier.issn0142-0615es_ES
dc.identifier.urihttps:doi.org10.1016j.ijepes.2023.109010es_ES
dc.descriptionArtículos en revistases_ES
dc.description.abstractes-ES
dc.description.abstractPower system stabilisers (PSSs) are commonly used in synchronous generators for damping low-frequency oscillations. However, many of these machines have been replaced by converter-interfaced generators (CIGs), such as those used in solar power plants. This means that CIG-based power plants should also contribute to oscillation damping. Moreover, CIGs may use both active and reactive power for power oscillation damping (POD). However, their combined use has been seldom studied in the literature. Moreover, only a few articles have addressed the adaption of POD controllers when the power system changes (e.g., after a fault). In this paper, a POD controller for CIG-based power plants is proposed that is suitable for operation in power systems exposed to reconfiguration. This controller takes advantage of both active and reactive power injection to maximise the damping of the power system. This controller is based only on local measurements so communication systems are not required. Theoretical developments were validated in a laboratory using real power converters including a 75 kVA grid emulator where the two-area benchmark model is emulated and four 15 kVA CIGs operating in parallel connection. The applicability of the proposed controller was also explored for the IEEE 39-bus system.en-GB
dc.format.mimetypeapplication/octet-streames_ES
dc.language.isoen-GBes_ES
dc.sourceRevista: International Journal of Electrical Power & Energy Systems, Periodo: 1, Volumen: online, Número: , Página inicial: 109010-1, Página final: 109010-10es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titlePower oscillation damping method suitable for network reconfigurations based on converter interfaced generation and combined use of active and reactive powerses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordses-ES
dc.keywordsPower oscillation damping; Low-frequency oscillations; Power modulation; Network reconfiguration; Power oscillation damping controlleren-GB


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

  • Artículos
    Artículos de revista, capítulos de libro y contribuciones en congresos publicadas.

Mostrar el registro sencillo del ítem