dc.description.abstract | El ciclotrón AMIT fue desarrollado como una colaboración liderada por el CIEMAT para producir un ciclotrón superconductor compacto y eficiente destinado a la producción de radioisótopos. Se fabricó el imán y su sistema criogénico de circuito cerrado, basado en helio enfriado por un solo criocooler ubicado remotamente. Durante la puesta en marcha, se produjo un accidente en la primera rampa de subida, dañando el sistema de soporte del imán. El sistema de alineación de las bobinas no pudo posicionarlas adecuadamente dentro del yugo de hierro, por lo que finalmente se decidió desmantelar todo el criostato para inspeccionar el estado real de las partes internas. Este artículo describe los problemas encontrados durante la puesta en marcha del imán y su sistema criogénico, las soluciones parciales implementadas y la apertura final del criostato. Las conclusiones se centran en las lecciones aprendidas para fabricar un imán superconductor compacto y de bajas pérdidas térmicas para la producción de radioisótopos, así como las recomendaciones para una versión mejorada y más confiable. | es-ES |
dc.description.abstract | The AMIT cyclotron was developed as a collaboration led by CIEMAT to produce a compact and efficient superconducting cyclotron for radioisotope production. The magnet and its closed loop cryogenic system, based on Helium cooled by means of just one remotely located cryocooler, was manufactured. During the commissioning there was an accident at the first ramp up and the magnet supporting system was damaged. The alignment system of the coils was not able to properly position the coils inside the iron yoke, so finally it was decided to dismantle the whole cryostat to check the actual state of the inner parts. This paper describes the issues found during the commissioning of the AMIT cyclotron magnet and its cryogenic system, the partial solutions implemented and the final aperture of the cryostat. The conclusions are focused on the lessons learnt for manufacturing such a compact and low thermal losses superconducting magnet for radioisotope production and the recommendations for an improved and more reliable version. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | es-ES | es_ES |
dc.rights | Creative Commons Reconocimiento-NoComercial-SinObraDerivada España | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | es_ES |
dc.source | Revista: IEEE Transactions on Applied Superconductivity, Periodo: 1, Volumen: 34, Número: 3, Página inicial: on-line, Página final: on-line | es_ES |
dc.title | Analysis of the Limitations of the AMIT Magnet During Its Commissioning | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.description.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.rights.holder | es_ES | |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
dc.keywords | Imanes superconductores, Blindaje magnético, Ruido magnético, Bobinas, Ciclotrones, Helio, Criogenia | es-ES |
dc.keywords | Superconducting magnets, Magnetic shielding, Magnetic noise, Coils, Cyclotrons, Helium, Cryogenics | en-GB |