dc.contributor.author | Rouco Rodríguez, Luis | es-ES |
dc.contributor.author | Antolín Liñán, María | es-ES |
dc.date.accessioned | 2025-03-04T18:08:04Z | |
dc.date.available | 2025-03-04T18:08:04Z | |
dc.date.issued | 2024-08-05 | es_ES |
dc.identifier.uri | http://hdl.handle.net/11531/97768 | |
dc.description | Capítulos en libros | es_ES |
dc.description.abstract | | es-ES |
dc.description.abstract | This paper proposes a reduced-order model for the simulation of back-to-back start-up of synchronous motors in pumped storage hydropower plants aimed at calculating the starting time of the generator-motor set. It is assumed that the back-to-back start-up process is governed by a predefined gate set point-time profile to the governor of the synchronous generator. Simulation of detailed and reduced-order models arecompared. Sensitivity analysis with respect to the parameters of the gate set point-time profile is presented. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | en-GB | es_ES |
dc.publisher | Sin editorial (Ischia, Italia) | es_ES |
dc.rights | | es_ES |
dc.rights.uri | | es_ES |
dc.source | Libro: 27th International Symposium on Power Electronics, Electrical Drives, Automation and Motion - SPEEDAM 2024, Página inicial: 706-711, Página final: | es_ES |
dc.subject.other | Instituto de Investigación Tecnológica (IIT) | es_ES |
dc.title | A reduced-order model for simulation of back-to- back start-up of synchronous motors in pumped storage hydropower plants | es_ES |
dc.type | info:eu-repo/semantics/bookPart | es_ES |
dc.description.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/restrictedAccess | es_ES |
dc.keywords | | es-ES |
dc.keywords | Pumped-storage power plants, Fixed-speed synchronous machines, back-to-back start-up, detailed model, reduced-order model. | en-GB |