Mostrar el registro sencillo del ítem
Fault ride through capability of round rotor synchronous generators: review, analysis and discussion of European grid code requirements
dc.contributor.author | Díez Maroto, Luis | es-ES |
dc.contributor.author | Rouco Rodríguez, Luis | es-ES |
dc.contributor.author | Fernández Bernal, Fidel | es-ES |
dc.date.accessioned | 2016-11-04T04:06:12Z | |
dc.date.available | 2016-11-04T04:06:12Z | |
dc.date.issued | 2016-11-01 | es_ES |
dc.identifier.issn | 0378-7796 | es_ES |
dc.identifier.uri | https:doi.org10.1016j.epsr.2016.06.046 | es_ES |
dc.description | Artículos en revistas | es_ES |
dc.description.abstract | es-ES | |
dc.description.abstract | A fault ride through (FRT) capability of synchronous generators is currently required by most grid codes, beyond what is required by International Electrotechnical Commission (IEC) and Institute of Electrical and Electronics Engineering (IEEE) standards for round rotor generators. This article reviews and compares FRT as required by European grid codes, and the European Network of Transmission System Operators for Electricity (ENTSO-E) grid code proposal. It investigates whether a typical round rotor turbogenerator fulfils the FRT requirements. The response of power plant auxiliaries is also analyzed. Recommendations to improve the formulation of FRT requirements are made based on thorough sensitivity studies of the response of such turbogenerators with respect to a number of variables and parameters. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | en-GB | es_ES |
dc.rights | es_ES | |
dc.rights.uri | es_ES | |
dc.source | Revista: Electric Power Systems Research, Periodo: 1, Volumen: online, Número: , Página inicial: 27, Página final: 36 | es_ES |
dc.subject.other | Instituto de Investigación Tecnológica (IIT) | es_ES |
dc.title | Fault ride through capability of round rotor synchronous generators: review, analysis and discussion of European grid code requirements | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.description.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/restrictedAccess | es_ES |
dc.keywords | es-ES | |
dc.keywords | Grid codes; Synchronous generators; Fault ride through capability; Transient stability; Reactive power capability; Auxiliaries | en-GB |