Sistema de medida de tensión arterial en dedos con fotopletismografía: sistema PPG.

Thumbnail
Ver/
TFGM (3.831Mb)
ANXI (333.3Kb)
Fecha
2018
Autor
Gil Borrallo, Felipe
Metadatos
Mostrar el registro completo del ítem
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Resumen
La medida de la presión arterial es un signo clínico clave para el diagnóstico de diferentes enfermedades. Sin embargo, los métodos utilizados actualmente para su medida (invasivo o con esfigmomanómetro) no son adecuados para un uso continuo y portátil. Se propone un método de medida de presión arterial consistente en la oclusión de una arteria digital, midiendo de manera simultánea el flujo de sangre con un sensor PPG. La presión sanguínea se estima de manera análoga al método auscultatorio (la mínima presión que bloquea el torrente sanguíneo será la presión sistólica, mientras que la máxima presión a la que la sangre fluye libremente sería la presión diastólica). Se ha desarrollado un prototipo de dicho sistema de medida: este documento se centra en el diseño del sensor PPG, que estará optimizado para la medida en la falange proximal de un dedo de la mano. Los resultados iniciales de las pruebas muestran una clara disminución de la amplitud de la señal PPG cuando se aumenta la presión aplicada sobre el dedo; no obstante, no se ha estudiado la correlación entre estos resultados y la presión arterial del individuo medida con por el método convencional. El sistema desarrollado se presenta como una alternativa prometedora de medida ambulatoria de presión arterial, aunque se requiere un mayor desarrollo del prototipo para poder integrar el sistema en un sensor biométrico de tipo wearable.
 
Blood pressure (BP) measurement is a key piece of information for the diagnosis of different kinds of diseases and medical conditions. However, the currently used measurement methods (invasive or with sphygmomanometer) are not suitable for continuous and mobile use. A method is proposed to measure blood pressure, consisting of the occlusion of a digital artery and the measurement of the blood circulation by means of a PPG sensor. The blood pressure would be estimated in an analogous way to the one used by sphygmomanometers (the minimum pressure which blocks blood flow would be the systolic pressure, while the maximum pressure at which the blood flows freely would be the diastolic one). A prototype of the system has been developed: this paper focuses on the design of the PPG sensor, which will be optimized for measuring in the proximal phalanx of a finger. Initial results of prototype testing are presented: a clear lowering of the PPG signal amplitude has been noted as the pressure on the finger is increased, although the correlation between the results and the subject BP measured by the standard sphygmomanometer-based method has not been carried out. Thus, the system presents itself as a promising blood pressure measurement system, although some further development of the prototype is needed to integrate the system into a wearable biometric sensor.
 
URI
http://hdl.handle.net/11531/22581
Trabajo Fin de Máster
Sistema de medida de tensión arterial en dedos con fotopletismografía: sistema PPG.
Titulación / Programa
Se trata de estudiar la viabilidad y en su caso diseñar un sistema que permita medir la tensión arterial mediante un sistema de oclusión de las arterias de los dedos, midiendo la misma con métodos fotopletismográficos. Esta parte se refiere al sistema de detección del flujo de sangre.
Materias/ categorías / ODS
MII-N (H62-electronica)
Palabras Clave
medida de presión arterial, PPG, oclusión, dedo, biométrica, sensor, esfigmomanómetro
blood pressure measurement, PPG, occlusion, finger, biometrics, sensor, sphygmomanometer
Colecciones
  • H62-Trabajos Fin de Máster

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias
 

 

Búsqueda semántica (CKH Explorer)


Listar

Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipoEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipo

Mi cuenta

AccederRegistro

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias