Mostrar el registro sencillo del ítem

dc.contributor.advisorCepeda Fernández, Fernandoes-ES
dc.contributor.authorBautista San Martín, Álvaroes-ES
dc.contributor.otherUniversidad Pontificia Comillas, Escuela Técnica Superior de Ingeniería (ICAI)es_ES
dc.date.accessioned2019-10-14T06:50:00Z
dc.date.available2019-10-14T06:50:00Z
dc.date.issued2020es_ES
dc.identifier.urihttp://hdl.handle.net/11531/42450
dc.descriptionGrado en Ingeniería en Tecnologías Industrialeses_ES
dc.description.abstractEl proyecto consiste en la climatización de un edificio de oficinas en León, realizado de acuerdo con las condiciones técnicas y legales que deben presentar las instalaciones, cumpliendo la normativa vigente, el RITE. Se climatizarán las 13 plantas, la primera planta, consta de un amplio vestíbulo de entrada al edificio, las siguientes plantas hasta la cubierta forman las oficinas con módulos de trabajo y pasillos de acceso, con un total de 44 zonas a climatizar. En primer lugar, se realizarán los cálculos de carga de invierno y verano. Se utilizarán las condiciones climatológicas más extremas de la ciudad de León, con una temperatura de -6 grados en invierno, 32 grados en verano y 8 grados de temperatura del terreno. Primero, se realizará el cálculo de cargas en verano, donde se tendrá en cuenta la orientación del edificio, las cargas transmitidas por radiación solar y por cerramientos. En el cálculo de cargas de invierno se tendrá en cuenta únicamente la transmisión por cerramiento, debido a que el resto de las cargas resultan favorables a la hora del cálculo. Una vez realizado el cálculo de cargas, se procederá a la elección de los climatizadores. Debido a que este proyecto se compone de zonas de baja carga se utilizarán únicamente fancoils. A través de los equipos situados en la cubierta, se tratará el aire exterior que será conducido a los fancoils por medio de conductos. Se realizará la dimensión de los conductos bajo los criterios de la norma. En cuanto al dimensionamiento de tuberías, dividimos en tuberías de impulso y retorno de agua fría y de agua caliente. Se tendrá en cuenta el caudal requerido para el fancoil y los criterios de la norma. En el dimensionamiento de las tuberías se incluirán las válvulas de bola, mariposa, retención y filtros. Por último, los equipos encargados de calentar y enfriar el agua se colocarán en la cubierta, ascendiendo el presente presupuesto a la cantidad de 702.928,51 euros.es-ES
dc.description.abstractThe project consists of the air conditioning of an office building in Leon, carried out in accordance with the technical and legal conditions that the installations must have, complying with current regulations: the RITE. The 13 floors will be air-conditioned, the first floor consists of a large entrance hall to the building, the following floors to the roof form the offices with work modules and access corridors, with a total of 44 areas to be air-conditioned. First of all, the winter and summer load calculations will be carried out. The most extreme weather conditions in the city of León will be used, with a temperature of -6 degrees in winter, 32 degrees in summer and 8 degrees in the ground. First, the summer load calculations will be carried out, taking into account the orientation of the building, the loads transmitted by solar radiation and by the enclosures. In the calculation of winter loads, only the transmission through the building envelope will be taken into account, since the rest of the loads are favourable at the time of calculation. Once the load calculation has been carried out, the selection of the air conditioners will be made. Due to the fact that this project is composed of low load zones, only fancoils will be used. Through the equipment located on the roof, the external air will be treated and will be led to the fancoils through ducts. The ducts will be dimensioned according to the criteria of the standard. Regarding the dimensioning of the pipes, we divide them into impulse and return pipes for cold water and hot water. The flow rate required for the fancoil and the criteria of the standard will be taken into account. The sizing of the pipes will include the ball valves, butterfly valves, check valves and filters. Finally, the equipment for heating and cooling the water will be placed on the deck, with the present budget amounting to 702,928.51 euros.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoes-ESes_ES
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United Stateses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/es_ES
dc.subject.otherKTI-mecanica (GITI-M)es_ES
dc.titleClimatización de un edificio de oficinas en Leónes_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.rights.accessRightsinfo:eu-repo/semantics/closedAccesses_ES
dc.keywordsClimatización, León, Fancoils, tuberías, Conductoses-ES
dc.keywordsAir conditioning, Leon, Fancoils, pipes, ductsen-GB


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivs 3.0 United States
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivs 3.0 United States