• English
    • español
  • English 
    • English
    • español
  • Login
View Item 
  •   Home
  • 2.- Investigación
  • Artículos
  • View Item
  •   Home
  • 2.- Investigación
  • Artículos
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Liquid chromatographic method development for anabolic androgenic steroids using a monolithic column Application to animal feed samples

Thumbnail
View/Open
IIT-08-085A.pdf (601.8Kb)
Date
01/03/2008
Author
Muñíz Valencia, Roberto
Gonzalo Lumbreras, Raquel
Santos Montes, Ana María
Izquierdo Hornillos, Roberto
Estado
info:eu-repo/semantics/publishedVersion
Metadata
Show full item record
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Abstract
 
 
An isocratic HPLC method for the determination with screening purposes of anabolic androgenic steroids (AASs: fluoxymesterone, boldenone, nortestosterone, metandrostenolone, norethindrone, methyltestosterone and bolasterone), used as growth promoting agents, in finishing pig feed samples has been developed and validated. The separation was achieved by using a reversed-phase Chromolith RP-18e column at controlled temperature, UV-detection at 245nm and epitestosterone as internal standard. The method development involved optimization of different aqueous-organic mobile phases using methanol or acetonitrile as organic modifiers, flow-rate and temperature. The optimum separation for these compounds was achieved at 40 degrees C using ultrapure water:acetonitrile (71:29, v/v) as mobile phase and 3mLmin(-1) flow-rate, allowing the separation of AASs with baseline resolution in about 15min. The optimized method was applied to the analysis of AASs in finishing pig feed samples. Prior to HPLC, sample preparation procedure was used by leaching using acetonitrile, saponification in a basic medium and solid-phase extraction using polymeric Abselut Nexus cartridges. Method validation has been carried out according to the European Commission Decision 2002/657/EC. The extraction efficiencies, decision limits (CCalpha) and detection capabilities (CCbeta) for these compounds were in the range 83-96\%, 27-37 and 32-47microgkg(-1) range, respectively. The within-laboratory reproducibility at 1, 1.5 and 2 CCbeta concentration levels were smaller than 13, 10 and 8\%, respectively. Finally, the proposed method was successfully applied to nine different kinds of animal feed.
 
URI
http://hdl.handle.net/11531/5251
Liquid chromatographic method development for anabolic androgenic steroids using a monolithic column Application to animal feed samples
Tipo de Actividad
Artículos en revistas
ISSN
0003-2670
Palabras Clave

Anabolic androgenic steroids; Growth promoting agents; Animal feed; Monolithic column
Collections
  • Artículos

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback
 

 

Búsqueda semántica (CKH Explorer)


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_typeThis CollectionBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_type

My Account

LoginRegister

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback