Vibration monitoring of electric generators without sensor dedicated
Fecha
2010-05-27Autor
Estado
info:eu-repo/semantics/publishedVersionMetadatos
Mostrar el registro completo del ítemResumen
This paper describes a method for on-line condition monitoring of rotating electric generators without a need for installed sensors dedicated. This sensorless method has been based on continuous monitoring vibration using neural networks for the classification of bearing failures experimentally induced. The results obtained have an error of less than 0,5 confirming the validity of the method proposed. This paper describes a method for on-line condition monitoring of rotating electric generators without a need for installed sensors dedicated. This sensorless method has been based on continuous monitoring vibration using neural networks for the classification of bearing failures experimentally induced. The results obtained have an error of less than 0,5 confirming the validity of the method proposed.
Vibration monitoring of electric generators without sensor dedicated