• English
    • español
  • English 
    • English
    • español
  • Login
View Item 
  •   Home
  • 2.- Investigación
  • Documentos de Trabajo
  • View Item
  •   Home
  • 2.- Investigación
  • Documentos de Trabajo
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Impact on power system transient stability of AC-line-emulation controllers of VSC-HVDC links

Thumbnail
View/Open
IIT-21-068C.pdf (1.138Mb)
Author
Renedo Anglada, Javier
Sigrist, Lukas
Rouco Rodríguez, Luis
García Cerrada, Aurelio
Estado
info:eu-repo/semantics/draft
Metadata
Show full item record
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Abstract
 
 
High voltage direct current links based on voltage source converters (VSC-HVDC) embedded in alternating current (AC) systems are receiving a great deal of attention recently because they can contribute positively to the flexibilisation of modern power systems. Among several possibilities, AC-lineemulation control has been highlighted as an simple-but-useful alternative for these type of systems.With this strategy, the power flow through the link is controlled proportionally to the angle difference between its two AC terminals and this provides selfadaptation of the power flow in case of contingencies in the parallel AC lines, naturally. Although this controller is mainly concerned with steady state, it can also have an impact on the dynamic behaviour of the system which has not been sufficiently analysed. Along this line, this paper analyses the impact of ACline-emulation controllers of VSC-HVDC on power system transient stability. Nonlinear time-domain simulations were carried out by using PSSE on a small test system with an embedded point-to-point VSC-HVDC link. The critical clearing time (CCT) of a test fault has been used to assess transient-stability margins of the whole system. The paper provides recommendations for the design of AC-line-emulation controllers in order to ensure that transient stability is not jeopardised.
 
URI
http://hdl.handle.net/11531/56211
Impact on power system transient stability of AC-line-emulation controllers of VSC-HVDC links
Palabras Clave

VSC-HVDC, AC-line emulation control, transient stability, power system stability
Collections
  • Documentos de Trabajo

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback
 

 

Búsqueda semántica (CKH Explorer)


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_typeThis CollectionBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_type

My Account

LoginRegister

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback