Mostrar el registro sencillo del ítem

dc.contributor.authorRivier Abbad, Juan Martínes-ES
dc.contributor.authorRouco Rodríguez, Luises-ES
dc.contributor.authorCastillo Campos, Juan Ignacio deles-ES
dc.contributor.authorVindel, D.es-ES
dc.contributor.authorVargas, Gregorioes-ES
dc.contributor.authorHerranz, A.es-ES
dc.date.accessioned2016-01-15T11:28:07Z
dc.date.available2016-01-15T11:28:07Z
dc.date.issued2003-08-25es_ES
dc.identifier.urihttp://hdl.handle.net/11531/5686
dc.descriptionCapítulos en libroses_ES
dc.description.abstractes-ES
dc.description.abstractThe usual lightning protection of high volt-age overhead lines is the usage of groundwires. In some cases, they cannot be used. This paper evaluates the effectiveness of different alternative protection schemes using surge arresters for a 132kV unshielded overhead line. The protection schemes are: a surge arrester at each conductor and tower, a surge arresters only at the central conductor and every tower (the configuration studied has the central conductor higher than lateral ones at therefore acts as a shield wire) and a surge arrester at each conductor and one out of two towers. The last two protective schemes are consid-ered due to economic reasons. Number of annual flashovers in a 100km line with the different protec-tion schemes is computed following IEEE recommen-dations. Direct, induced and back flashovers are con-sidered. Over-voltages are computed using the ATP software package, distinguishing between tower, cen-tral conductor and lateral conductor lightning strokes. Conclusions are presented about the effectiveness of each protective scheme.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.publisherSin editorial (Delft, España)es_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceLibro: XIIIth International Symposium on High Voltage Engineering (ISH 2003), Johan J. Smit Editor, Millpress (ISBN: 90-77017-79 8), pp. 137, Página inicial: , Página final:es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleEvaluation of lightning protection of unshielded 132kV overhead lines using surge arresterses_ES
dc.typeinfo:eu-repo/semantics/bookPartes_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsNo disponibleNot availableen-GB


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

  • Artículos
    Artículos de revista, capítulos de libro y contribuciones en congresos publicadas.

Mostrar el registro sencillo del ítem