Robust frequency constrained uc using data driven logistic regression for island power systems

Thumbnail
View/Open
Guía Docente.pdf (177.4Kb)
IIT-22-252R (2.226Mb)
IIT-22-252R_preview (2.976Kb)
Date
2022-12-01
Author
Rajabdorri, Mohammad
Lobato Miguélez, Enrique
Sigrist, Lukas
Director/Coordinador
Navarro Meléndez, Ana
Estado
info:eu-repo/semantics/publishedVersion
Metadata
Show full item record
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Abstract
 
 
In the current practice of short-term power scheduling, online power reserves are used to address generation mismatches and contingencies. Neither online inertia nor the speed of the committed units is considered in the scheduling process. With the increasing injection of uncertain renewable energy sources, this practice is starting to fall short, especially in island power systems, where the primary frequency response is already scarce, and any contingency leads to potentially poor frequency response. This paper introduces a data-driven linear constraint to improve the post-fault frequency quality in island power systems. A coherent initial data-set is obtained by simulating the system frequency response of single outages. Then logistic regression is employed as a predictive analytic procedure to differentiate the acceptable and unacceptable incidents. To compare the conventional methods with the proposed approach and also to handle the uncertain nature of renewable energy generation, an adaptive robust unit commitment formulation is utilized. Results for the island power system of La Palma show that depending on the chosen cut-point on the logistic regression estimation the proposed method can improve the frequency response quality of the system while reducing the operation costs.
 
URI
https:doi.org10.1049gtd2.12658
Robust frequency constrained uc using data driven logistic regression for island power systems
Tipo de Actividad
Artículos en revistas
Créditos
3.0
ISSN
1751-8687
Materias/ categorías / ODS
Instituto de Investigación Tecnológica (IIT)
Palabras Clave


Collections
  • KFS-Guías Docentes

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback
 

 

Búsqueda semántica (CKH Explorer)


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_typeThis CollectionBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_type

My Account

LoginRegister

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback