dc.description.abstractEl objetivo del presente proyecto es el cálculo, estudio y diseño de los elementos que constituyen la instalación para el suministro en baja tensión de un edificio destinado a sede social de un despacho de abogados. El edificio será de nueva construcción y se situará en la nueva expansión del Distrito Castellana Norte de Madrid. Con una superficie total de 3.917,44 m2, constará de planta principal, tres plantas en altura, cubierta y dos sótanos. Se dispondrán tres cuadros generales, y veintidós cuadros secundarios, distribuidos según las instalaciones de cada planta. El Cuadro General de Red estará alimentado desde el centro de transformación y, en condiciones normales de funcionamiento, alimentará a la totalidad de cargas del edificio. El Cuadro General de Grupo, en caso de fallo en la red, pasará a estar alimentado por el grupo electrógeno instalado en la cubierta del edificio, garantizando la continuidad del suministro a las cargas más sensibles y alumbrado de emergencia. En último lugar, al Cuadro de SAI (Sistema de Alimentación Ininterrumpida) se conectarán los equipos informáticos, asegurando una alimentación continua y de calidad. Las diversas cargas del edificio se han agrupado en circuitos de alumbrado y fuerza, elaborando un balance de potencia para estimar la carga total demandada por el edificio. A partir de dicho balance se concluye que el transformador a instalar ha de ser de 630 kVA y el grupo electrógeno de 125 kVA. Así mismo, esta previsión de cargas ha permitido calcular la sección de cable necesaria en cada circuito, realizando dicho cálculo tanto por intensidad admisible como por caída de tensión. El proyecto incluye el diseño y cálculo del centro de transformación que abastece al edificio y que se situará en el primer sótano. Se tratará de un centro de transformación de abonado, propiedad del cliente, siendo la red de entrada de la compañía suministradora. La ventilación será natural, habiendo calculado las superficies necesarias de entrada y salida de aire. Los equipos de medida y protección se albergarán en celdas modulares de media tensión. Para el cálculo de la puesta a tierra se han considerado dos puestas a tierras diferentes, la de baja tensión y la del centro de transformación, diseñando los electrodos de ambas de manera que garanticen tanto la seguridad de las personas como la integridad de los aparatos del sistema cuando se produzcan situaciones anómalas. Otros elementos destacados considerados en el proyecto han sido el cálculo de las protecciones de los circuitos, protección frente al rayo, equipo de compensación de energía reactiva, sistemas de carga de coches eléctricos y cálculo de la instalación de paneles solares en la cubierta del edificio. Todo ello respetando los reglamentos y normativa vigente.es_ES
dc.description.abstractThe objective of this project is the design, study and calculation of the elements constituting a low voltage supply facility for a law firm headquarters building. The structure will be built and located at the new urban expansion of the Northern Castellana District in Madrid. With a 3.917,44 m2 total area, it will be made up of a ground floor, three floors in height, cover and two basements. Three general electric switchboards and twenty two secondary boards (distributed according to each plant facilities needs) will be installed. The General Grid Board will be supplied from the transformation center and, under normal operating conditions, it will satisfy the whole of the building loads. The General Group Board, in case of failure in the network, will be powered by the electric generator installed on the roof of the building, ensuring continuous supply to the most sensitive loads and emergency lighting elements. Finally, UPS (Uninterruptible Power Supply) computer equipment will be connected, guaranteeing continuous, quality power. Building loads will be classified in two categories, which are lighting and power circuits, and as a result of those calculations the power balance will be determined in order to estimate the total load demanded. From that, one concludes that the transformer must be sized for an apparent power of 630 kVA, and for 125 kVA in the case of the electric generator. Also, this calculation has allowed us to determine the wire section required for each individual circuit, being this process made by admissible current and voltage drop. The project includes the design and calculation of the transformer center, located in the first basement floor, which supplies the building. It will be a subscriber’s power transforming center, which is property of the client, with the input grid supply owned by the company. Ventilation system is natural, as the necessary input and output air surfaces show that it is the most efficient system given this case. Measurement devices and protection equipment will be housed in modular, medium voltage switchgears. One of the main aspects regarding this project is the design and calculation of the different lighting elements facilities, for which DIALux calculation software has been used. A modern and efficient design is proposed, always complying with the values established by the Technical Building Code. Most of these lights used are based on LED technology, due to the energy savings involved (sustainability is also a secondary objective to be reached). Basements, as they are considered wet areas, are lighted by watertight luminaries, like inside the transformer. The building will be equipped with natural light and presence sensors so further energy can be saved. It has also been performed the calculation and design of lighting in the outdoor garden area, which includes the lighting of an ornamental water fountain. For ground calculations two different configurations have been considered, one for the low voltage and another one for the transformer. Both systems electrodes ere designed in a way that safety of people and the integrity of the devices when abnormal situations occur is ensured. Other remarkable elements considered in the project have been circuit protection devices, lightning protection equipment, reactive power compensation systems, electric car charging facilities and solar panel installation on the roof; always complying with proper rules and regulations.es_ES
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoeses_ES
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subject33 Ciencias tecnológicases_ES
dc.subject3306 Ingeniería y tecnología eléctricaes_ES
dc.titleProyecto de electrificación de un edificio destinado a sede social de un despacho de abogadoses_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivs 3.0 United States
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivs 3.0 United States