Mostrar el registro sencillo del ítem

dc.contributor.authorÁlvarez Coedo, Diegoes-ES
dc.contributor.authorAyala Santamaría, Pabloes-ES
dc.contributor.authorCantizano González, Alexises-ES
dc.contributor.authorWegrzynski, Wojcieches-ES
dc.date.accessioned2023-03-14T10:21:09Z
dc.date.available2023-03-14T10:21:09Z
dc.date.issued14/06/2022es_ES
dc.identifier.issn2214-157Xes_ES
dc.identifier.uri10.1016/j.csite.2022.102202es_ES
dc.identifier.urihttp://hdl.handle.net/11531/77452
dc.descriptionArtículos en revistases_ES
dc.description.abstractes-ES
dc.description.abstractThis paper presents the validation of a coupled hybrid (1D/3D-CFD) modelling methodology, using FDS version 6.7.5, for the first time, with full-scale fire tests. Real fire conditions of the Runehamar tests with maximum heat release rates of 6 MW, 66 MW, and 119 MW are compared by assessing temperature profiles, centreline velocity, backlayering lengths, and maximum temperatures at different locations both upstream and downstream from the fire source. An expression to evaluate the length of the 3D domain where the fire is located is successfully assessed. Also, a pressure boundary condition at one of the portals is suggested to predict more precisely the inner flow conditions. The temperature profiles are accurately predicted with time-averaged differences lower than 20% beyond 40 m downstream from the fire source in the three tests. Furthermore, with the coupled hybrid approach, the backlayering length is estimated accurately with the fire of 66 MW and underestimated in the 6 MW and 119 MW fires, i.e. a maximum difference lower than 4% of the total tunnel length. The validated proposed methodology allows accurate predictions of temperature for tunnel fires and reduces the computational cost between 27% and 75% with respect to a full-CFD numerical model.en-GB
dc.format.mimetypeapplication/octet-streames_ES
dc.language.isoen-GBes_ES
dc.sourceRevista: Case Studies in Thermal Engineering, Periodo: 1, Volumen: online, Número: , Página inicial: 102202-1, Página final: 102202-10es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleA coupled hybrid numerical study of tunnel longitudinal ventilation under fire conditionses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordses-ES
dc.keywordsCFD; Coupled hybrid modelling; Tunnel ventilation; Tunnel fire; FDS; Full-scale testsen-GB


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

  • Artículos
    Artículos de revista, capítulos de libro y contribuciones en congresos publicadas.

Mostrar el registro sencillo del ítem