dc.description.abstractThis paper studies the impact of Voltage Source Converter (VSC) losses on the solution of the Optimal Power Flow (OPF) of hybrid AC/DC systems with a multi-terminal configuration. The motivation of this analysis is that the expected development of High Voltage Direct Current (HVDC) systems will entail an increase of the number of converter stations, and consequently, converter losses might not be negligible when compared with conventional transmission losses of AC and DC lines. Towards this end, an extended OPF model is proposed considering a combination of VSC based Multi-Terminal HVDC grids (VSC-MTDC) and AC systems. The OPF model represents converter losses according to the state-of-the art modeling where different expressions are used when the converter functions as an inverter or as a rectifier. Three simpler alternative approaches are also implemented and the obtained OPF solutions are assessed. In order to compare the OPF solutions, a comparison metric is proposed. Obtained results show that modeling the converter losses in a simplified way could lead to very different power flow solutions, especially for the DC branches.es-ES
dc.description.abstractThis paper studies the impact of Voltage Source Converter (VSC) losses on the solution of the Optimal Power Flow (OPF) of hybrid AC/DC systems with a multi-terminal configuration. The motivation of this analysis is that the expected development of High Voltage Direct Current (HVDC) systems will entail an increase of the number of converter stations, and consequently, converter losses might not be negligible when compared with conventional transmission losses of AC and DC lines. Towards this end, an extended OPF model is proposed considering a combination of VSC based Multi-Terminal HVDC grids (VSC-MTDC) and AC systems. The OPF model represents converter losses according to the state-of-the art modeling where different expressions are used when the converter functions as an inverter or as a rectifier. Three simpler alternative approaches are also implemented and the obtained OPF solutions are assessed. In order to compare the OPF solutions, a comparison metric is proposed. Obtained results show that modeling the converter losses in a simplified way could lead to very different power flow solutions, especially for the DC branches.es
dc.description.abstractThis paper studies the impact of Voltage Source Converter (VSC) losses on the solution of the Optimal Power Flow (OPF) of hybrid AC/DC systems with a multi-terminal configuration. The motivation of this analysis is that the expected development of High Voltage Direct Current (HVDC) systems will entail an increase of the number of converter stations, and consequently, converter losses might not be negligible when compared with conventional transmission losses of AC and DC lines. Towards this end, an extended OPF model is proposed considering a combination of VSC based Multi-Terminal HVDC grids (VSC-MTDC) and AC systems. The OPF model represents converter losses according to the state-of-the art modeling where different expressions are used when the converter functions as an inverter or as a rectifier. Three simpler alternative approaches are also implemented and the obtained OPF solutions are assessed. In order to compare the OPF solutions, a comparison metric is proposed. Obtained results show that modeling the converter losses in a simplified way could lead to very different power flow solutions, especially for the DC branches.en
dc.description.versioninfo:eu-repo/semantics/publishedVersion
dc.format.mimetypeapplication/pdf
dc.identifier.issn0378-7796
dc.identifier.urihttps://doi.org/10.1016/j.epsr.2017.06.004
dc.keywordsOptimal Power Flow, Multi-Terminal HVDC, AC/DC Transmission System, Cost Minimization, Converter Losseses-ES
dc.keywordsOptimal Power Flow, Multi-Terminal HVDC, AC/DC Transmission System, Cost Minimization, Converter Losseses
dc.keywordsOptimal Power Flow, Multi-Terminal HVDC, AC/DC Transmission System, Cost Minimization, Converter Lossesen
dc.language.isoen-GB
dc.rightses_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.holderes_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceRevista: Electric Power Systems Research, Periodo: 1, Volumen: online, Número: , Página inicial: 395, Página final: 403
dc.subject.otherInstituto de Investigación Tecnológica (IIT)
dc.titleImpact of converter losses on the optimal power flow solution of hybrid networks based on VSC-MTDC
dc.typeinfo:eu-repo/semantics/article

Files

Original bundle

Now showing 1 - 3 of 3
Loading...
Thumbnail Image
Name:
IIT-17-110A.pdf
Size:
1010.19 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
IIT-17-110A_preview
Size:
2.92 KB
Format:
Unknown data format
Loading...
Thumbnail Image
Name:
IIT-17-110A_preview.pdf
Size:
2.92 KB
Format:
Adobe Portable Document Format

Collections