Emerging innovations in health metrology for diagnostic imaging

dc.contributor.authorEsteban Temprano, Ángelaes-ES
dc.contributor.authorde Castro Asensio, Inéses-ES
dc.contributor.authorDelgado San Martín, Lauraes-ES
dc.contributor.authorSáenz Nuño, María Anaes-ES
dc.contributor.authorFernández Vicente, Teresa Esperanzaes-ES
dc.contributor.authorPeña Rubio, Lourdeses-ES
dc.contributor.authorSáez Serrano, Aliciaes-ES
dc.contributor.authorSánchez Blaya, Carmenes-ES
dc.date.accessioned2025-03-04T17:47:31Z
dc.date.available2025-03-04T17:47:31Z
dc.date.issued2025-05-01es_ES
dc.descriptionArtículos en revistases_ES
dc.description.abstractThe Spanish National Metrology Center (CEM) is dedicated to advance the understanding of the essential role of measurements in the healthcare sector. CEM has created a laboratory in healthcare metrology to ensure the accuracy of measurements in medical equipment, including computed tomography (CT). The primary objective of this project is to design a system considered as a standard, called Phantometer, which allows the traceability of dimensional measurements obtained from diagnostic imaging to the International System of Units (SI). For this purpose, the Phantometer has been graphically designed and numerical simulations have been performed to examine its response to environmental conditions and to evaluate the relative contributions of uncertainty to the dimensional measurements, primarily due to thermal and mechanical forces and torsion sources. Subsequently, the standard undergoes metrological characterization in dimensional terms, and the results are disseminated to the research community.es-ES
dc.description.abstractThe Spanish National Metrology Center (CEM) is dedicated to advance the understanding of the essential role of measurements in the healthcare sector. CEM has created a laboratory in healthcare metrology to ensure the accuracy of measurements in medical equipment, including computed tomography (CT). The primary objective of this project is to design a system considered as a standard, called Phantometer, which allows the traceability of dimensional measurements obtained from diagnostic imaging to the International System of Units (SI). For this purpose, the Phantometer has been graphically designed and numerical simulations have been performed to examine its response to environmental conditions and to evaluate the relative contributions of uncertainty to the dimensional measurements, primarily due to thermal and mechanical forces and torsion sources. Subsequently, the standard undergoes metrological characterization in dimensional terms, and the results are disseminated to the research community.en-GB
dc.description.abstract<p id="abspara0010" class="u-margin-s-bottom">The Spanish National Metrology Center (CEM) is dedicated to advance the understanding of the essential role of measurements in the healthcare sector.</p> <p id="abspara0015" class="u-margin-s-bottom">CEM has created a laboratory in healthcare metrology to ensure the accuracy of measurements in medical equipment, including computed tomography (CT). The primary objective of this project is to design a system considered as a standard, called Phantometer, which allows the traceability of dimensional measurements obtained from diagnostic imaging to the International System of Units (SI).</p> <p id="abspara0020" class="u-margin-s-bottom">For this purpose, the Phantometer has been graphically designed and numerical simulations have been performed to examine its response to environmental conditions and to evaluate the relative contributions of uncertainty to the dimensional measurements, primarily due to thermal and mechanical forces and torsion sources.</p> <p id="abspara0025" class="u-margin-s-bottom">Subsequently, the standard undergoes metrological characterization in dimensional terms, and the results are disseminated to the research community.</p>es
dc.description.abstract<p id="abspara0010" class="u-margin-s-bottom">The Spanish National Metrology Center (CEM) is dedicated to advance the understanding of the essential role of measurements in the healthcare sector.</p> <p id="abspara0015" class="u-margin-s-bottom">CEM has created a laboratory in healthcare metrology to ensure the accuracy of measurements in medical equipment, including computed tomography (CT). The primary objective of this project is to design a system considered as a standard, called Phantometer, which allows the traceability of dimensional measurements obtained from diagnostic imaging to the International System of Units (SI).</p> <p id="abspara0020" class="u-margin-s-bottom">For this purpose, the Phantometer has been graphically designed and numerical simulations have been performed to examine its response to environmental conditions and to evaluate the relative contributions of uncertainty to the dimensional measurements, primarily due to thermal and mechanical forces and torsion sources.</p> <p id="abspara0025" class="u-margin-s-bottom">Subsequently, the standard undergoes metrological characterization in dimensional terms, and the results are disseminated to the research community.</p>en
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.identifier.issn2665-9174es_ES
dc.identifier.urihttps://doi.org/10.1016/j.measen.2024.101649es_ES
dc.keywordsCEM; Diagnostic imaging; Health; Phantometer; Standard; Traceability; Uncertaintyes-ES
dc.keywordsCEM; Diagnostic imaging; Health; Phantometer; Standard; Traceability; Uncertaintyen-GB
dc.keywordsCEM; Diagnostic imaging; Health; Phantometer; Standard; Traceability; Uncertaintyes
dc.keywordsCEM; Diagnostic imaging; Health; Phantometer; Standard; Traceability; Uncertaintyen
dc.language.isoen-GB
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.holderes_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceRevista: Measurement: Sensors, Periodo: 1, Volumen: online, Número: Supplement, Página inicial: 101649-1, Página final: 101649-5es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleEmerging innovations in health metrology for diagnostic imaginges_ES
dc.typeinfo:eu-repo/semantics/articlees_ES

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
IIT-25-009R.pdf
Size:
3.42 MB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
IIT-25-009R_preview.pdf
Size:
3.02 KB
Format:
Adobe Portable Document Format

Collections