CCGT unit commitment model with first-principle formulation of cycling costs due to fatigue damage

dc.contributor.authorWogrin, Sonjaes-ES
dc.date.accessioned2016-07-21T03:05:48Z
dc.date.available2016-07-21T03:05:48Z
dc.date.issued2016-10-15
dc.descriptionArtículos en revistas
dc.description.abstractCombined cycle gas turbine power plants (CCGTs) play a key role in modern electric power systems due to their operational flexibility and the firmness they provide to the networks where they operate. Due in part to this flexibility and firmness, the function of CCGTs has experienced a significant evolution with the advent of intermittent renewable energy sources such as wind: CCGTs are increasingly required to rapidly vary load levels in order to counterbalance the fluctuations of renewable energy sources and satisfy overall system demand. The purpose of this paper is to develop a methodology that can be used for assessing the optimal operational strategy of a CCGT when subjected to cycling requirements. This is achieved by introducing a unit commitment formulation that takes into account useful life expenditure costs due to fatigue damage accumulation associated to cycling. The case studies presented in this paper show that neglecting fatigue cycling costs when making operational decisions generates suboptimal cost and profit outcomes for CCGT operators. Furthermore, it is shown that profitability of CCGTs is compromised in systems with very significant penetration of intermittent renewable energy sources, due to the increase in cycling costs derived from continuous load-following operation.es-ES
dc.description.versioninfo:eu-repo/semantics/publishedVersion
dc.format.mimetypeapplication/pdf
dc.identifier.issn0360-5442
dc.identifier.urihttps://doi.org/10.1016/j.energy.2016.07.014
dc.keywordsCCGT; Combined cycle plants; Cycling costs; Fatigue damage; Unit commitment model; Wind penetrationes-ES
dc.language.isoen-GB
dc.rightses_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.holderes_ES
dc.rights.uries_ES
dc.sourceRevista: Energy, Periodo: 1, Volumen: online, Número: , Página inicial: 227, Página final: 247
dc.subject.otherInstituto de Investigación Tecnológica (IIT)
dc.titleCCGT unit commitment model with first-principle formulation of cycling costs due to fatigue damage
dc.typeinfo:eu-repo/semantics/article

Files

Original bundle

Now showing 1 - 3 of 3
Loading...
Thumbnail Image
Name:
IIT-16-114A.pdf
Size:
1.42 MB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
IIT-16-114A_preview
Size:
2.91 KB
Format:
Unknown data format
Loading...
Thumbnail Image
Name:
IIT-16-114A_preview.pdf
Size:
2.91 KB
Format:
Adobe Portable Document Format

Collections