Hydrogen Blending in Iberian Gas-Electricity Networks using Mixed Integer Linear Programming
| dc.contributor.author | Laguna Domínguez, Jorge | es-ES |
| dc.contributor.author | Campos Fernández, Francisco Alberto | es-ES |
| dc.date.accessioned | 2026-09-30T04:59:55Z | |
| dc.date.issued | 2026-10-08 | |
| dc.description.abstract | This paper develops an hourly optimization model coupling hydrogen (H2) and natural-gas (NG) transport with electricity dispatch through combined-cycle gas turbines (CCGT). Mixed gas nonlinearities are approximated using McCormick relaxations and a tangent-based pressure-flow approximation. An iterative concentration reconstruction and bound-refinement procedure reduces the mixing inconsistencies, while fixed flow directions and relaxed thermal commitments make the weekly management tractable. A 2030 Iberian case study compares hydrogen mass-fraction limits from zero to 2.8% during a representative week. H2 utilization ranges from nearly 0% to 85.7%, showing that H2 injection potential strongly depends on project location, downstream gas demand, available NG dilution and network flow and pressure constraints. Increasing the maximum H2 mass fraction from 0.7% to 2.8% raises avoided direct CO2 emissions from 4.08 to 17.88 kt. The impact on CCGT generation is comparatively small, while gas composition, flows and pressures are more significantly affected. | es-ES |
| dc.description.abstract | This paper develops an hourly optimization model coupling hydrogen (H2) and natural-gas (NG) transport with electricity dispatch through combined-cycle gas turbines (CCGT). Mixed gas nonlinearities are approximated using McCormick relaxations and a tangent-based pressure-flow approximation. An iterative concentration reconstruction and bound-refinement procedure reduces the mixing inconsistencies, while fixed flow directions and relaxed thermal commitments make the weekly management tractable. A 2030 Iberian case study compares hydrogen mass-fraction limits from zero to 2.8% during a representative week. H2 utilization ranges from nearly 0% to 85.7%, showing that H2 injection potential strongly depends on project location, downstream gas demand, available NG dilution and network flow and pressure constraints. Increasing the maximum H2 mass fraction from 0.7% to 2.8% raises avoided direct CO2 emissions from 4.08 to 17.88 kt. The impact on CCGT generation is comparatively small, while gas composition, flows and pressures are more significantly affected. | en-GB |
| dc.description.version | info:eu-repo/semantics/draft | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.uri | http://hdl.handle.net/11531/115389 | |
| dc.keywords | H2 blending, gas-electricity coupling, integer programming, McCormick relaxation, Iberian energy system | es-ES |
| dc.keywords | H2 blending, gas-electricity coupling, integer programming, McCormick relaxation, Iberian energy system | en-GB |
| dc.language.iso | en-GB | |
| dc.rights.accessRights | info:eu-repo/semantics/restrictedAccess | |
| dc.title | Hydrogen Blending in Iberian Gas-Electricity Networks using Mixed Integer Linear Programming | |
| dc.type | info:eu-repo/semantics/workingPaper |
Files
License bundle
1 - 1 of 1
Loading...
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: