Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/100552
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Jiménez Octavio, Jesús Ramón | es-ES |
dc.contributor.author | Carpintero Rubio, Carlos Javier | es-ES |
dc.contributor.author | Sochor, Mark | es-ES |
dc.contributor.author | Asensio Gil, Juan Manuel | es-ES |
dc.contributor.author | Rodríguez-Morcillo García, Carlos | es-ES |
dc.contributor.author | López Valdés, Francisco José | es-ES |
dc.date.accessioned | 2025-07-10T14:21:21Z | - |
dc.date.available | 2025-07-10T14:21:21Z | - |
dc.date.issued | 2025-06-01 | es_ES |
dc.identifier.issn | 2076-3417 | es_ES |
dc.identifier.uri | https:doi.org10.3390app15116167 | es_ES |
dc.identifier.uri | http://hdl.handle.net/11531/100552 | - |
dc.description | Artículos en revistas | es_ES |
dc.description.abstract | es-ES | |
dc.description.abstract | The human neck is highly vulnerable in motor vehicle crashes, and cervical spine response data are essential to improve injury prediction tools (e.g., crash test dummies, human body models). This feasibility study aimed to implement the use of pressure sensors in whole-body post-mortem human subject (PMHS) cervical spine intervertebral discs (IVDs) to confirm the feasibility and repeatability of cervical IVD pressure response to biomechanic research. Two fresh frozen whole-body PMHSs were instrumented with miniature pressure sensors (Model 060S, Precision Measurement Company, Ann Arbor, MI, USA) at three cervical IVD levels (C3C4, C5C6, and C7T1) using minimally invasive surgical insertion techniques. Each PMHS underwent three quasistatic motion test trials, and each trial included multiple headneck motions (i.e., gentle traction, flexionextension, lateral bending, axial rotation, and forced tensioncompression). Results showed marked pressure differences between both the cervical level assessed and the motion undertaken as well as successful intra-subject repeatability between the three motion trials. This study demonstrates that changes in cervical IVD pressure are associated with motion events of the cervical spine. Cervical IVD response data could be utilized to assess and supplement the characterization of the headneck complex motion, and data could facilitate the continued improvement of injury prediction tools. | en-GB |
dc.language.iso | en-GB | es_ES |
dc.source | Revista: Applied Sciences, Periodo: 1, Volumen: online, Número: 11, Página inicial: 6167-1, Página final: 6167-17 | es_ES |
dc.subject.other | Instituto de Investigación Tecnológica (IIT) | es_ES |
dc.title | Human Cervical Intervertebral Disc Pressure Response During Non-Injurious Quasistatic Motion: A Feasibility Study | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.description.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.rights.holder | es_ES | |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
dc.keywords | es-ES | |
dc.keywords | biomechanics; cervical spine; neck; intervertebral disc; cadaver; whole body; PMHS; pressure; injury prevention; non-injurious | en-GB |
Aparece en las colecciones: | Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
IIT-25-160R | 3,6 MB | Unknown | Visualizar/Abrir | |
IIT-25-160R_preview | 3,7 kB | Unknown | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.