Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/107134
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorTruyols Vives, Joanes-ES
dc.contributor.authorGonzález López, Martaes-ES
dc.contributor.authorColom Fernández, Antonies-ES
dc.contributor.authorEinschütz López, Alexanderes-ES
dc.contributor.authorSala Llinàs, Ernestes-ES
dc.date.accessioned2025-11-12T12:43:40Z-
dc.date.available2025-11-12T12:43:40Z-
dc.date.issued2025-07-12es_ES
dc.identifier.issn2305-6304es_ES
dc.identifier.uri10.3390/toxics13070583es_ES
dc.descriptionArtículos en revistases_ES
dc.description.abstractLa sala donde se admitieron los pacientes con síntomas leves tenía una mayor ocupación, tránsito de personas en el pasillo y niveles de CO2, pero no hubo diferencias significativas en la detección de SARS-CoV 2 entre las salas. La concentración media de CO2 en las muestras positivas fue de 569 ± 35,6 ppm. Considerando todas las muestras, los niveles de CO2 en el pasillo se correlacionaron positivamente con las aperturas de las puertas de los pacientes, pero inversamente con los niveles de SARS-CoV-2. En conclusión, el SARS-CoV-2 en el aire puede detectarse en interiores con una ventilación óptima, y ​​sus niveles no se correlacionan con la concentración de CO2 en los pasillos del hospital. Por lo tanto, la evaluación de CO2 no debe interpretarse como un indicador de la presencia viral en el aire en todos los espacios interiores.es-ES
dc.description.abstractIndoors, the infection risk of diseases transmitted through the airborne route is estimated from indoor carbon dioxide (CO2) levels. However, the approaches to assess this risk do not account for the airborne concentration of pathogens, among other limitations. In this study, we analyzed the relationship between airborne SARS-CoV-2 levels and environmental parameters. Bioaerosols were sampled (n = 40) in hospital corridors of two wards differing in the COVID-19 severity of the admitted patients. SARS-CoV-2 levels were quantified using droplet digital PCR. SARS-CoV-2 was detected in 60% of the total air samples. The ward where the mildly ill patients were admitted had a higher occupancy, transit of people in the corridor, and CO2 levels, but there were no significant differences in SARS-CoV 2 detection between wards. The mean CO2 concentration in the positive samples was 569 ± 35.6 ppm. Considering all samples, the CO2 levels in the corridor were positively correlated with patient door openings but inversely correlated with SARS-CoV-2 levels. In conclusion, airborne SARS-CoV-2 can be detected indoors with optimal ventilation, and its levels do not scale with CO2 concentration in hospital corridors. Therefore, CO2 assessment should not be interpreted as a surrogate of airborne viral presence in all indoor spaces.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightsCreative Commons Reconocimiento-NoComercial-SinObraDerivada Españaes_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/es_ES
dc.sourceRevista: Toxics, Periodo: 1, Volumen: 13, Número: 7, Página inicial: 1, Página final: 13es_ES
dc.titleAirborne SARS-CoV-2 Detection by ddPCR in Adequately Ventilated Hospital Corridorses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordsSARS-CoV-2; transmisión aérea; ddPCR; bioaerosol; dióxido de carbono.es-ES
dc.keywordsSARS-CoV-2; airborne transmission; ddPCR; bioaerosol; carbon dioxide.en-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Tamaño Formato  
2025111023138995_toxics-13-00583.pdf1,08 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.