dc.contributor.authorRouco Rodríguez, Luises-ES
dc.contributor.authorEchavarren Cerezo, Franciscoes-ES
dc.contributor.authorLobato Miguélez, Enriquees-ES
dc.date.accessioned2026-02-02T09:12:43Z-
dc.date.available2026-02-02T09:12:43Z-
dc.date.issued2026-03-01es_ES
dc.identifier.issn2352-4677es_ES
dc.identifier.urihttps://doi.org/10.1016/j.segan.2026.102125es_ES
dc.identifier.urihttp://hdl.handle.net/11531/108473-
dc.descriptionArtículos en revistases_ES
dc.description.abstractThe Iberian Peninsula blackout on 28th April 2025 occurred due to cascading disconnection of renewable generation with power factor control, triggered by overvoltage generation protections. This paper describes a conceptual model to explain the primary phenomenon that occurred, which we have called an overvoltage-driven blackout. While the phenomenon of voltage collapse, or more precisely undervoltage collapse, is widely discussed in the scientific literature, the phenomenon of an overvoltage-driven blackout is new. An illustrative 3-bus small-scale power system is provided to better understand the evolution of bus voltages in an overvoltage-driven blackout, identifying the critical factors that can lead a power system to a blackout caused by overvoltage. The conceptual model is applied to the state of the Iberian Peninsula electricity system at 12:30 on 28th April 2025, preceding the blackout. The paper will show how, with the loss of renewable generation, the growth of bus voltages exhibits the same pattern as the one identified in the 3-bus small-scale system. A new safety metric (margin to overvoltage-driven blackout) is defined and computed. The paper will demonstrate how the system operated with an insufficient safety margin, leading to an overvoltage-driven blackout, due to a lack of sufficient synchronous reactive power absorption capacity in the central and southern parts of Spain, as well as the low-loaded transmission grid in those regions.es-ES
dc.description.abstractThe Iberian Peninsula blackout on 28th April 2025 occurred due to cascading disconnection of renewable generation with power factor control, triggered by overvoltage generation protections. This paper describes a conceptual model to explain the primary phenomenon that occurred, which we have called an overvoltage-driven blackout. While the phenomenon of voltage collapse, or more precisely undervoltage collapse, is widely discussed in the scientific literature, the phenomenon of an overvoltage-driven blackout is new. An illustrative 3-bus small-scale power system is provided to better understand the evolution of bus voltages in an overvoltage-driven blackout, identifying the critical factors that can lead a power system to a blackout caused by overvoltage. The conceptual model is applied to the state of the Iberian Peninsula electricity system at 12:30 on 28th April 2025, preceding the blackout. The paper will show how, with the loss of renewable generation, the growth of bus voltages exhibits the same pattern as the one identified in the 3-bus small-scale system. A new safety metric (margin to overvoltage-driven blackout) is defined and computed. The paper will demonstrate how the system operated with an insufficient safety margin, leading to an overvoltage-driven blackout, due to a lack of sufficient synchronous reactive power absorption capacity in the central and southern parts of Spain, as well as the low-loaded transmission grid in those regions.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.sourceRevista: Sustainable Energy, Grids and Networks, Periodo: 1, Volumen: online, Número: , Página inicial: 102125-1, Página final: 102125-9es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleThe overvoltage-driven blackout of the Iberian Peninsula on 28th April 2025es_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordsVoltage collapse; Voltage control; Ancillary serviceses-ES
dc.keywordsVoltage collapse; Voltage control; Ancillary servicesen-GB