Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/109169
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorGutiérrez Florensa, Joanes-ES
dc.contributor.authorAnderson-Azzano, Jorge L.es-ES
dc.contributor.authorPuleston, Paul F.es-ES
dc.contributor.authorOrtega Manjavacas, Álvaroes-ES
dc.contributor.authorSigrist, Lukases-ES
dc.date.accessioned2026-03-16T12:50:48Z-
dc.date.available2026-03-16T12:50:48Z-
dc.date.issued2026-01-12es_ES
dc.identifier.urihttp://hdl.handle.net/11531/109169-
dc.descriptionCapítulos en libroses_ES
dc.description.abstractThe present paper evaluates different sliding mode control techniques for the negative-sequence current injection of voltage source converters under low-voltage ride-through scenarios. Under such scenarios those devices are required, from the grid code specifications, to inject reactive power to help mitigate voltage sag situations. The implicit unbalanced and faulted conditions of this scenario demands a robust enough control strategy to ensure system stability. The robustness requirements and the variety of scenarios justify the consideration of sliding mode for current control. However, the control method is also required to exhibit a smooth and rapid performance during steady-state operation conditions. Among the studied cases an adaptive super-twisting algorithm present better results for this application when considering long-term operation. The implementation of these control techniques might imply challenges on line protections. HiL application is discussed in order to assess the challenges and key considerations that need to be addressed.es-ES
dc.description.abstractThe present paper evaluates different sliding mode control techniques for the negative-sequence current injection of voltage source converters under low-voltage ride-through scenarios. Under such scenarios those devices are required, from the grid code specifications, to inject reactive power to help mitigate voltage sag situations. The implicit unbalanced and faulted conditions of this scenario demands a robust enough control strategy to ensure system stability. The robustness requirements and the variety of scenarios justify the consideration of sliding mode for current control. However, the control method is also required to exhibit a smooth and rapid performance during steady-state operation conditions. Among the studied cases an adaptive super-twisting algorithm present better results for this application when considering long-term operation. The implementation of these control techniques might imply challenges on line protections. HiL application is discussed in order to assess the challenges and key considerations that need to be addressed.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.publisherIEEE Control Systems Society (Río de Janeiro, Brasil)es_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceLibro: 64th IEEE Conference on Decision and Control - CDC 2025, Página inicial: 7969-7974, Página final:es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleSliding Mode Control Techniques for Voltage Source Converters under Low-Voltage Ride-Through Scenarioses_ES
dc.typeinfo:eu-repo/semantics/bookPartes_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordsCurrent control , Low voltage , Reactive power , Power system stability , Stability analysis , Robustness , Steady-state , Voltage control , Sliding mode control , Voltage-source converterses-ES
dc.keywordsCurrent control , Low voltage , Reactive power , Power system stability , Stability analysis , Robustness , Steady-state , Voltage control , Sliding mode control , Voltage-source convertersen-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Tamaño Formato  
IIT-25-409C.pdf1,27 MBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.