| dc.contributor.author | Sendín Escalona, Alberto | es-ES |
| dc.contributor.author | Berganza Valmala, Iñigo | es-ES |
| dc.contributor.author | Arzuaga, Aitor | es-ES |
| dc.contributor.author | Pulkkinen, Anssi | es-ES |
| dc.contributor.author | Kim, Il Han | es-ES |
| dc.date.accessioned | 2026-03-27T06:54:01Z | - |
| dc.date.available | 2026-03-27T06:54:01Z | - |
| dc.date.issued | 2013-03-25 | es_ES |
| dc.identifier.issn | 2474-2902 | es_ES |
| dc.identifier.uri | 10.1109/SmartGridComm.2012.6485974 | es_ES |
| dc.identifier.uri | http://hdl.handle.net/11531/109393 | - |
| dc.description | Artículos en revistas | es_ES |
| dc.description.abstract | Este artículo presenta los resultados del despliegue de más de 100.000 contadores inteligentes basados en tecnología PRIME en España. Se describe la arquitectura de red utilizada, así como las estrategias de despliegue y los factores que afectan al rendimiento de las comunicaciones PLC en redes de baja tensión. Además, se propone una clasificación de subestaciones secundarias basada en parámetros como el número y la densidad de puntos de suministro. El estudio incluye herramientas de monitorización y análisis del rendimiento, así como resultados reales obtenidos en distintos escenarios (urbanos, rurales e industriales). Los resultados demuestran la viabilidad de la tecnología PRIME para despliegues a gran escala, destacando altos niveles de disponibilidad y estabilidad, así como la importancia de procesos de validación y monitorización en redes inteligentes. | es-ES |
| dc.description.abstract | PRIME (Powerline Intelligent Metering Evolution) is a narrowband PLC technology designed for smart metering applications. This paper presents the results of a large-scale deployment of over 100,000 smart meters in Spain. It describes the communication architecture used by Iberdrola, deployment strategies, and factors affecting system performance such as noise, impedance, and network topology. A classification of secondary substations based on field parameters is proposed. The study also introduces tools for monitoring and analyzing network performance. Results obtained from different deployment scenarios demonstrate high availability and stability of PRIME networks, confirming their suitability for large-scale smart grid implementations and highlighting the importance of systematic validation and troubleshooting processes. | en-GB |
| dc.format.mimetype | application/pdf | es_ES |
| dc.language.iso | en-GB | es_ES |
| dc.rights | Creative Commons Reconocimiento-NoComercial-SinObraDerivada España | es_ES |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | es_ES |
| dc.source | Revista: IEEE International Conference on Smart Grid Communications, Periodo: 1, Volumen: ., Número: ., Página inicial: 145, Página final: 150 | es_ES |
| dc.title | Performance Results from 100,000+ PRIME Smart Meters Deployment in Spain | es_ES |
| dc.type | info:eu-repo/semantics/article | es_ES |
| dc.description.version | info:eu-repo/semantics/publishedVersion | es_ES |
| dc.rights.holder | es_ES | |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
| dc.keywords | Medición inteligente, Comunicaciones PLC, Redes eléctricas inteligentes, PRIME, Despliegue a gran escala, Monitorización | es-ES |
| dc.keywords | Smart metering, Power line communications, Smart grid, PRIME, Large scale deployment, Monitoring | en-GB |