Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/12808
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorSánchez Martín, Pedroes-ES
dc.contributor.authorCorrea-Posada, Carlos M.es-ES
dc.contributor.authorMorales España, German Andreses-ES
dc.contributor.authorDueñas Martínez, Pabloes-ES
dc.date.accessioned2016-09-14T17:14:03Z-
dc.date.available2016-09-14T17:14:03Z-
dc.date.issued08/06/2016es_ES
dc.identifier.issn1949-3029es_ES
dc.identifier.urihttp://hdl.handle.net/11531/12808-
dc.descriptionArtículos en revistases_ES
dc.description.abstractEl crecimiento de la generación renovable en todo el mundo está dando lugar a nuevos retos para una operación segura, fiable y económica de los sistemas eléctricos de potencia. De cara a afrontar los retos de una producción de fuentes renovables que son variables e intermitentes, las reservas de operación deben ser gestionadas eficientemente y de manera precisa. A día de hoy, estas reservas son principalmente asignadas a unidades térmicas, especificamente plantas de gas, debido a su flexibilidad en la operación y su respuesta rápida. Sin embargo, las capacidades de las rampas de estas unidades definen el nivel de flexibilidad ofrecida a la operación del sistema eléctrico. De forma práctica, estas rampas son dinámicas, es decir, que son una función de la potencia de salida de la unidad. Omitir este aspecto lleva a tomar decisiones subóoptimas o incluso decisiones no factibles, incrementando finalmente los requerimientos de reserva operativa y también las transacciones que los mercados de balance de energía en tiempo real debidas a las deviaciones de la generación renovable. Este artículo contribuye con un modelo de programación mixto entero considerando las rampas dinámicas de las unidades permitiendo cambios intraperiodo en el problema de asignación de unidades. Como resultado, las reservas operativas están mejor gestionadas y la flexibilidad de las unidades se aprovecha de forma más eficiente que los modelos de rampas tradicionales encontrados en la literatura. Diferentes casos de estudio ilustran el funcionamiento y los beneficios de la formulación propuesta.es-ES
dc.description.abstractThe growing increase of renewable generation worldwide is posing new challenges for a secure, reliable and economic operation of power systems. In order to face the uncertain and intermittent production of renewable sources, operating reserves must be allocated efficiently and accurately. Nowadays, these reserves are mainly assigned to thermal units, especially gas-fired generators, due to their operation flexibility and fast response. However, the ramping capabilities of these units define the grade of flexibility offered to the system operation. In practical applications, ramping limits are dynamic, i.e., they are a function of the unit s generating output. Omitting this feature leads to suboptimal or even infeasible reserve allocations, thus increasing not only operating reserve requirements but also transactions in real-time balancing markets needed to back up deviations of renewable generation. This paper contributes with a mixedinteger linear programming model for units dynamic ramping allowing intraperiod changes in the unit commitment problem. As a result, operating reserves are better allocated and the units flexibility is managed more efficiently than traditional ramping models found in the literature. Different case studies illustrate the functioning and benefits of the proposed formulation.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: IEEE Transactions on Sustainable Energy, Periodo: 3, Volumen: PP, Número: 99, Página inicial: 1, Página final: 1es_ES
dc.titleDynamic ramping model including intraperiod ramp-rate changes in unit commitmentes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderCopyright IEEEes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordsRampas dinámicas, programación lineal entera mixta, reservas, acoplamiento de unidades de generación, unidades de generación térmicaes-ES
dc.keywordsDynamic ramping, mixed-integer linear programming, reserves, unit commitment, thermal units.en-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
V4 1_TC-Dynamic Ramping in Power-Based UC - PROOF.pdf231,17 kBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.