Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/15542
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Fernández Bernal, Fidel | es-ES |
dc.contributor.author | Egido Cortés, Ignacio | es-ES |
dc.contributor.author | Lobato Miguélez, Enrique | es-ES |
dc.date.accessioned | 2016-12-01T04:10:09Z | - |
dc.date.available | 2016-12-01T04:10:09Z | - |
dc.date.issued | 2014-05-23 | es_ES |
dc.identifier.uri | http://hdl.handle.net/11531/15542 | - |
dc.description | Capítulos en libros | es_ES |
dc.description.abstract | es-ES | |
dc.description.abstract | The increasing demand coverage by wind power is posing new challenges to the operation of power systems. In this paper the effect on secondary reserve necessary to overcome the added uncertainty is analyzed. Maximun wind power demand coverage, limited by the secondary reserve value requirement, is assessed. The Spanish power system is used for numerical application using real data. Maximum demand coverage of around 60 - 80 is possible without compromising secondary reserve value. An increase of 70 - 200 in secondary reserve is expected for a demand coverage of around 60. Some dynamic performance considerations on the secondary regulation are given for the Spanish case. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | en-GB | es_ES |
dc.publisher | Sin editorial (Kuala Lumpur, Malasia) | es_ES |
dc.rights | es_ES | |
dc.rights.uri | es_ES | |
dc.source | Libro: IEEE PES International Conference on Innovative Smart Grid Technologies Asia - ISGT Asia 2014, Página inicial: , Página final: | es_ES |
dc.subject.other | Instituto de Investigación Tecnológica (IIT) | es_ES |
dc.title | Secondary reserve limitation to wind power penetratrion in the Spanish power system | es_ES |
dc.type | info:eu-repo/semantics/bookPart | es_ES |
dc.description.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/restrictedAccess | es_ES |
dc.keywords | es-ES | |
dc.keywords | Wind power generation; load frecuency control; secondary reserve; ancillary services | en-GB |
Aparece en las colecciones: | Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
IIT-14-043A.pdf | 3,33 MB | Adobe PDF | Visualizar/Abrir Request a copy |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.