Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/21304
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Ochoa Giménez, Miguel | es-ES |
dc.contributor.author | García Cerrada, Aurelio | es-ES |
dc.contributor.author | Zamora Macho, Juan Luis | es-ES |
dc.date.accessioned | 2017-09-01T11:20:36Z | - |
dc.date.available | 2017-09-01T11:20:36Z | - |
dc.date.issued | 2017-07-01 | es_ES |
dc.identifier.issn | 2196-5625 | es_ES |
dc.identifier.uri | https:doi.org10.1007s40565-017-0303-2 | es_ES |
dc.description | Artículos en revistas | es_ES |
dc.description.abstract | es-ES | |
dc.description.abstract | This paper presents a comprehensive control strategy for unified power quality conditioners (UPQCs) to compensate for both voltage and current quality problems. The controllers for the series and shunt components of the UPQC are, equally, divided into three blocks: 1. main controller, which deals with the fundamental-frequency issues such as active and reactive power flow; 2. harmonic controller, which ensures zero-error tracking while compensating voltage and current harmonics; 3. the set-point generation block, which handles the different control objectives of the UPQC. The controller design procedure has been simplified to the selection of three parameters for each converter. Furthermore, the proposed strategy can be implemented measuring only four variables, which represents a reasonable number of sensors. In addition, a pulse width modulation (PWM)-based modulation with fixed switching frequency is used for both converters. The proposed control strategy has been validated experimentally under different conditions, including grid-frequency variations. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | en-GB | es_ES |
dc.source | Revista: Journal of Modern Power Systems and Clean Energy, Periodo: 1, Volumen: online, Número: 4, Página inicial: 609, Página final: 619 | es_ES |
dc.subject.other | Instituto de Investigación Tecnológica (IIT) | es_ES |
dc.title | Comprehensive control for unified power quality conditioners | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.description.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.rights.holder | es_ES | |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
dc.keywords | es-ES | |
dc.keywords | Unified power quality conditioner (UPQC), Power quality, Harmonic control | en-GB |
Aparece en las colecciones: | Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
IIT-17-014A.pdf | 2,75 MB | Adobe PDF | ![]() Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.