Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/23831
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorPipkorn, Bengtes-ES
dc.contributor.authorLópez Valdés, Francisco Josées-ES
dc.contributor.authorJuste Lorente, Oscares-ES
dc.contributor.authorInsausti, Ricardoes-ES
dc.contributor.authorLundgren, Christeres-ES
dc.contributor.authorSunnevang, Ceciliaes-ES
dc.date.accessioned2017-11-09T07:26:06Z-
dc.date.available2017-11-09T07:26:06Z-
dc.date.issued02/09/2016es_ES
dc.identifier.issn1538-9588es_ES
dc.identifier.urihttp://hdl.handle.net/11531/23831-
dc.descriptionArtículos en revistases_ES
dc.description.abstractEvaluación de sistemas de retención innovadoreses-ES
dc.description.abstractObjectives: The objective of this study was to determine the potential chest injury benefits and influence on occupant kinematics of a belt system with independent control of the shoulder and lap portions. Methods: This article investigates the kinematics and dynamics of human surrogates in 35 km/h impacts with 2 different restraints: a pretensioning (PT), force-limiting (FL) seat belt, a reference belt system, and a concept design with a split buckle consisting (SB) of 2 separate shoulder and lap belt bands. The study combinesmathematical simulations with the THOR dummy and THUMS human body model, andmechanical tests with the THOR dummy and 2 postmortem human surrogate (PMHS) tests of similar age (39 and 42 years) and anthropometry (62 kg, 181 cm vs. 60 kg, 171.5 cm). The test setup consisted of a rigid metallic frame representing a standard seating position of a right front passenger. The THOR dummy model predictions were compared to the mechanical THOR dummy test results. The THUMS-predicted number of fractured ribs were compared to the number of fractured ribs in the PMHS. Results: THOR sled tests showed that the SB seat belt system decreased chest deflection significantly without increasing the forward displacement of the head. The THOR model and the THOR physical dummy predicted a 13- and 7-mm reduction in peak chest deflection, respectively. Peak diagonal belt force in the mechanical test with the reference belt was 5,582 N and the predicted force was 4,770 N. The THOR model also predicted lower belt forces with the SB system than observed in the tests (5,606 vs. 6,085 N). THUMS predicted somewhat increased head displacement for the SB system compared to the reference system. Peak diagonal force with the reference belt was 4,000 N and for the SB system it was 5,200 N. The PMHS test with the SB belt resulted in improved kinematics and a smaller number of rib fractures (2 vs. 5 fractures) compared to the reference belt. Conclusion: Concepts for a belt system that can reduce the load on the chest of the occupant in a crash and thereby reduce the number of injured occupants, in particular the elderly, was proposed.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: Traffic Injury Prevention, Periodo: 1, Volumen: 17, Número: sup1, Página inicial: 124, Página final: 130es_ES
dc.titleAssessment of an innovative seat belt with independent control of the shoulder and lap portions using THOR tests, the THUMS model, and PMHS testses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderexiste copyrightes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordsPost Mortem Human Surrogates, cinturón de seguridad, impacto frontal, THOR, THUMSes-ES
dc.keywordsPMHS, seat belt, frontal impact, THOR, THUMSen-GB
Aparece en las colecciones: Artículos



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.