Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/29938
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorRoldan Perez, Javieres-ES
dc.contributor.authorGarcía Cerrada, Aurelioes-ES
dc.contributor.authorRodríguez Cabero, Albertoes-ES
dc.contributor.authorZamora Macho, Juan Luises-ES
dc.date.accessioned2018-08-30T02:45:14Z-
dc.date.available2018-08-30T02:45:14Z-
dc.date.issued2018-08-01es_ES
dc.identifier.issn1996-1073es_ES
dc.identifier.urihttps:doi.org10.3390en11081972es_ES
dc.descriptionArtículos en revistases_ES
dc.description.abstractes-ES
dc.description.abstractVoltage sags result in unwanted operation stops and large economical losses in industrial applications. A dynamic voltage restorer (DVR) is a power-electronics-based device conceived to protect high-power installations against these events. However, the design of a DVR control system is not straightforward and it has some peculiarities. First of all, a DVR includes a resonant (LC) connection filter with a lightly damped resonance. Secondly, the control system of a DVR should work properly regardless of the type of load, which can be linear or non-linear, to be protected. In this paper, a digital state-feedback (SF) controller for a DVR is proposed to address these issues. The design and features of the SF controller are studied in detail. Two pole-placement alternatives are discussed and the system robustness is tested under variations in the system parameters. Furthermore, implementation aspects such as discretization not commonly addressed in the literature are described. The controller is implemented in its incremental form. A decoupling system for the dq-axis dynamics that takes into account system delays and the load current is proposed and analytically studied. The proposed controller is compared with two other alternatives found in the literature: a Proportional-Integral-Differential (PID) controller and a cascade controller. The effect of the load connected downstream a DVR is also studied, revealing the potential of the SF controller to damp the resonance under light load conditions. All control system developments were tested in a 5 kVA prototype of a DVR connected to a configurable grid.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.sourceRevista: Energies, Periodo: 1, Volumen: online, Número: 8, Página inicial: 1972-1, Página final: 1972-26es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleComprehensive design and analysis of a state-feedback controller for a dynamic voltage restoreres_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordses-ES
dc.keywordsAC-DC power converters; dynamic voltage restorer (DVR); voltage sags; state-feedback controller; discrete-time control systemsen-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IIT-18-098A.pdf2,03 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.