Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/32094
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Martín Escudero, Pilar | es-ES |
dc.contributor.author | Miguel-Tobal, Francisco | es-ES |
dc.contributor.author | Dotor Castilla, María Luisa | es-ES |
dc.contributor.author | López-Silva, Sonnia María | es-ES |
dc.contributor.author | Giannetti, Romano | es-ES |
dc.contributor.author | Galindo Canales, Mercedes | es-ES |
dc.date.accessioned | 2018-10-03T02:47:55Z | - |
dc.date.available | 2018-10-03T02:47:55Z | - |
dc.date.issued | 04/07/2018 | es_ES |
dc.identifier.uri | http://hdl.handle.net/11531/32094 | - |
dc.description | Capítulos en libros | es_ES |
dc.description.abstract | es-ES | |
dc.description.abstract | Oximetry is a method used to assess peripheral blood oxygen saturation based on the determination of the level of red light absorption, directly influenced by the hemoglobin levels. Most studies on pulse oximetry, within the scope of sports medicine and clinic, have been performed in male populations, with few studies in female populations. The objective of our study was to determine transcutaneous oxygen saturation in sportswomen of different races and to analyze the correlation of this determination with the first (VT1) and second (VT2) ventilatory thresholds. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | en-GB | es_ES |
dc.publisher | European College of Sport Science; Gatorade Sports Science Institute; Catapult; European Journal of (Dublín, Irlanda) | es_ES |
dc.rights | es_ES | |
dc.rights.uri | es_ES | |
dc.source | Libro: 23rd Annual Congress of the European College of Sport Science - ECSS Dublin 2018, Página inicial: , Página final: | es_ES |
dc.subject.other | Instituto de Investigación Tecnológica (IIT) | es_ES |
dc.title | Oxygen saturation through pulse oximetry in sportswomen | es_ES |
dc.type | info:eu-repo/semantics/bookPart | es_ES |
dc.description.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/restrictedAccess | es_ES |
dc.keywords | es-ES | |
dc.keywords | Instrumentación electrónica, Metrología sanitaria | en-GB |
Aparece en las colecciones: | Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
IIT-18-086A_ abstract.pdf | 130,94 kB | Adobe PDF | Visualizar/Abrir Request a copy |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.