Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/33289
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Mata García, Luis Javier | es-ES |
dc.contributor.author | Reinoso Otero, Paloma | es-ES |
dc.contributor.other | Universidad Pontificia Comillas, Escuela Técnica Superior de Ingeniería (ICAI) | es_ES |
dc.date.accessioned | 2018-11-19T17:07:56Z | - |
dc.date.available | 2018-11-19T17:07:56Z | - |
dc.date.issued | 2019 | es_ES |
dc.identifier.uri | http://hdl.handle.net/11531/33289 | - |
dc.description | Grado en Ingeniería Electromecánica | es_ES |
dc.description.abstract | El presente proyecto desarrolla la implantación de energía solar térmica y fotovoltaica en un hotel en Córdoba como alternativa para cubrir parte de su demanda térmica y energética. Esta energía servirá para abastecer parte de los consumos de agua caliente sanitaria (ACS), calefacción mediante suelo radiante, climatización de piscinas y electricidad. Se ha elegido para el proyecto el hotel Eurostars Palace situado en la provincia de Córdoba debido a que Andalucía cuenta con un elevado potencial de energías renovables y es pionera en el uso de energía eólica y termosolar. Para establecer las características de la instalación solar térmica que se pretende diseñar, se han analizado las condiciones de radiación solar mensuales de Córdoba y las condiciones ambientales de la zona como la temperatura media ambiental y la temperatura media del agua de red mensuales. Se dimensionan captadores solares, bombas para la alimentación de los circuitos primario y secundario e interacumuladores. Se eligen también las tuberías, válvulas y demás elementos necesarios. Se consigue un ahorro próximo al 60 % en las demandas de A.C.S, y del 30% para la calefacción por suelo radiante y la climatización de la piscina exterior. Para la generación solar fotovoltaica se elige un sistema basado en el autoconsumo sin excedentes. Tras diversos análisis se seleccionan los siguientes componentes: panel fotovoltaico, inversor y regulador de carga. Optimizando la disposición de los paneles elegidos se consigue cubrir un 5,3% de la demanda total. Tras realizar el presupuesto con los costes iniciales derivados de los elementos que componen las instalaciones solares térmica y fotovoltaica que se van a instalar, la mano de obra y el estudio de seguridad y salud, y teniendo en cuenta que la Agencia Andaluza de la Energía ofrece subvenciones del 30% para instalaciones se obtiene una INVERSIÓN INICIAL CON SUBVENCIÓN de 415.411,53 €. Tras el estudio de viabilidad económica se concluye que la instalación comenzará a ser rentable a partir del 12º año. Se analizan como alternativas complementarias el desarrollo de cada instalación solar individualmente. Si se instalara solo térmica, comenzaría a ser rentable a partir del 6º año. Se instala un sistema de monitorización para recoger y procesar la información proveniente de la instalación solar térmica y fotovoltaica. Este proyecto supone, además de un ahorro económico gracias al aprovechamiento de una fuente de energía gratuita que se recibe de manera directa, un paso hacia la independencia de las fuentes energéticas externas y convencionales. Permite mejorar la competitividad de la empresa al mismo tiempo que reduce el daño ambiental, pues contribuye a frenar los efectos que se derivan de la emisión de gases nocivos para el medio. | es-ES |
dc.description.abstract | This project develops the implementation of solar thermal and photovoltaic energy in a hotel in Cordoba as an alternative to cover part of its thermal and electric demand. This energy will serve to supply part of the consumption of domestic hot water (DHW), radian soil, pool heating and electricity. The Eurostars Palace hotel located in the province of Córdoba has been chosen because Andalusia has a high potential for renewable energies and is also a pioneer in the use of wind and solar power to produce electricity. To establish the characteristics of the solar thermal installation that is intended to be designed, the monthly solar radiation conditions of Córdoba and the environmental conditions of the area have been analyzed, such as the average environmental temperature and the monthly average water temperature of the network. Solar collectors have been dimensioned, pumps that feed the primary and secondary circuits and storage cylinders. Pipes, valves and other necessary elements have also been selected. Savings of close to 60% are achieved in the demands of A.C.S, and 30% for underfloor heating and air conditioning of the outdoor pool. For photovoltaic solar generation, a system based on self-consumption without surplus is chosen. After several analyzes, the following components have been selected: photovoltaic panel, inverter and charge regulator. By optimizing the layout of the chosen panels, it is possible to cover 5.3% of the total demand. After making the budget with the initial costs derived from the elements that make up the solar thermal and photovoltaic installations that will be installed, the year of construction and the study of safety and health, and taking into account that the Andalusian Energy Agency offers subsidies of 30% for installations you get an INITIAL INVESTMENT WITH A GRANT of € 415,411.53. After the economic feasibility study, it is concluded that the installation will start to be profitable after the 12th year. The development of each solar installation individually is analyzed as complementary alternatives. If it were installed only thermal, it would start to be profitable from the 6th year. A monitoring system has been installed to collect and process the information coming from the solar thermal and photovoltaic installation. This project involves, in addition to an economic saving thanks to the use of a free energy source that is received directly, a step towards the independence of external and conventional energy sources. It improves the competitiveness of the company while reducing environmental damage, as it helps to curb the effects that result from the emission of harmful gases to the environment. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | es-ES | es_ES |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 United States | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | es_ES |
dc.subject.other | IEM-E (KL0-elecrica) | es_ES |
dc.title | Eficiencia Energética con renovables en un hotel | es_ES |
dc.type | info:eu-repo/semantics/bachelorThesis | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/closedAccess | es_ES |
dc.keywords | Energía solar, fotovoltaica, térmica, balance neto, eficiencia energétic, autoconsumo | es-ES |
dc.keywords | Solar energy, photovoltaic, thermal solar, net balance, energy efficiency, self-consumption | en-GB |
Aparece en las colecciones: | KL0-Trabajos Fin de Grado |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
TFG- REINOSO OTERO, PALOMA.pdf | Trabajo Fin de Grado | 4,21 MB | Adobe PDF | Visualizar/Abrir |
20190703163706.pdf | Autorización | 290 kB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.