Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/43588
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorRenedo Anglada, Javieres-ES
dc.contributor.authorGarcía Cerrada, Aurelioes-ES
dc.contributor.authorRouco Rodríguez, Luises-ES
dc.contributor.authorSigrist, Lukases-ES
dc.date.accessioned2019-11-27T04:16:54Z-
dc.date.available2019-11-27T04:16:54Z-
dc.date.issued2019-10-01es_ES
dc.identifier.issn1996-1073es_ES
dc.identifier.urihttps://doi.org/10.3390/en12193638es_ES
dc.descriptionArtículos en revistases_ES
dc.description.abstractPower transmission is the main purpose of high voltage direct current systems based on voltage source converters (VSC-HVDC). Nevertheless, this type of system can also help to improve transient stability by implementing suitable supplementary controllers. Previous work proposed active- (P) and reactive-power (Q) control strategies in VSC-HVDC multi-terminal systems (VSC-MTDC, for short) to improve transient stability, producing significant improvements. In those strategies, each VSC station of the MTDC system compares its frequency measurement with the average of the frequencies measured by all converter stations of the MTDC system (weighted-average frequency, WAF) in order to modulate its own P and Q injections. Hence, a communication system is required. This paper presents a detailed analysis of the impact of communication latency on the performance of those control strategies. The communication delays have been modelled using a Padé’s approximation and their impact on the performance of the control strategies have been assessed by means of time-domain simulation in PSS/E. The effect of the control strategies on transient stability has been quantified with the critical clearing time (CCT) of a set of faults. Results show that the control strategies analysed present good results for realistic values of communication delays.es-ES
dc.description.abstractPower transmission is the main purpose of high voltage direct current systems based on voltage source converters (VSC-HVDC). Nevertheless, this type of system can also help to improve transient stability by implementing suitable supplementary controllers. Previous work proposed active- (P) and reactive-power (Q) control strategies in VSC-HVDC multi-terminal systems (VSC-MTDC, for short) to improve transient stability, producing significant improvements. In those strategies, each VSC station of the MTDC system compares its frequency measurement with the average of the frequencies measured by all converter stations of the MTDC system (weighted-average frequency, WAF) in order to modulate its own P and Q injections. Hence, a communication system is required. This paper presents a detailed analysis of the impact of communication latency on the performance of those control strategies. The communication delays have been modelled using a Padé’s approximation and their impact on the performance of the control strategies have been assessed by means of time-domain simulation in PSS/E. The effect of the control strategies on transient stability has been quantified with the critical clearing time (CCT) of a set of faults. Results show that the control strategies analysed present good results for realistic values of communication delays.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.sourceRevista: Energies, Periodo: 1, Volumen: online, Número: 19, Página inicial: 3638-1, Página final: 3638-32es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleCoordinated control in VSC-HVDC Multi- terminal systems to improve transient stability: the impact of communication latencyes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordspower systems; high voltage direct current (HVDC) transmission; HVDC systems based on voltage source converters (VSC-HVDC); multi-terminal; transient stability; control strategies; communication latencyes-ES
dc.keywordspower systems; high voltage direct current (HVDC) transmission; HVDC systems based on voltage source converters (VSC-HVDC); multi-terminal; transient stability; control strategies; communication latencyen-GB
dc.identifier.doi10.3390/en12193638es_ES
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IIT-19-094A.pdf1,78 MBAdobe PDFVista previa
Visualizar/Abrir
IIT-19-094A1,78 MBUnknownVisualizar/Abrir
IIT-19-094A_preview3,31 kBUnknownVisualizar/Abrir
IIT-19-094A1,78 MBUnknownVisualizar/Abrir
IIT-19-094A_preview.pdf3,31 kBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.