Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/43590
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorRenedo Anglada, Javieres-ES
dc.contributor.authorRouco Rodríguez, Luises-ES
dc.contributor.authorGarcía Cerrada, Aurelioes-ES
dc.contributor.authorSigrist, Lukases-ES
dc.date.accessioned2019-11-27T04:17:17Z-
dc.date.available2019-11-27T04:17:17Z-
dc.date.issued2019-09-01es_ES
dc.identifier.issn0378-7796es_ES
dc.identifier.urihttps:doi.org10.1016j.epsr.2019.04.032es_ES
dc.descriptionArtículos en revistases_ES
dc.description.abstractes-ES
dc.description.abstractThis paper proposes a new reactive-power control strategy for High Voltage Direct Current multi-terminal systems with Voltage Source Converter stations (VSC-HVDC) to improve transient stability in electric power transmission systems. The proposed algorithm uses local measurements to estimate, in each converter station, a weighted average of the frequencies seen by the VSC stations of the HVDC multi-terminal system. This estimation is carried out making use of a (small) auxiliary local active-power modulation along with the DC-side voltage droop control in the VSC stations, where the latter also uses local measurements only. The estimated frequency is used as the set point for supplementary reactive-power control at each converter station. The proposed control law has been simulated in a test system using PSSE and the results show that it improves transient stability, significantly, producing similar results to those obtained controlling reactive power using global measurements.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: Electric Power Systems Research, Periodo: 1, Volumen: online, Número: , Página inicial: 105854-1, Página final: 105854-13es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleA communication-free reactive-power control strategy in VSC-HVDC multi-terminal systems to improve transient stabilityes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsVSC HVDC; Multi-terminal; Transient stability; Reactive power control; Power systems; Local measurementsen-GB
dc.identifier.doi10.1016/j.epsr.2019.04.032es_ES
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IIT-19-045A.pdf5,28 MBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.