Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/45463
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorMoreno Pérez, Diegoes-ES
dc.contributor.authorMarín, Pedro J.es-ES
dc.contributor.authorLópez Samanes, Álvaroes-ES
dc.contributor.authorCejuela Anta, Robertoes-ES
dc.contributor.authorEsteve Lanao, Jonathanes-ES
dc.date.accessioned2020-03-17T13:11:49Z-
dc.date.available2020-03-17T13:11:49Z-
dc.date.issued2020-02-26es_ES
dc.identifier.issn1424-8220es_ES
dc.identifier.uri10.3390/s20051268es_ES
dc.descriptionArtículos en revistases_ES
dc.description.abstractEl objetivo fue evaluar cambios en la actividad electomiográfica con el uso de medias de compresión gradual en atletas de mediofondo, basándonos en técnicas de electromiografía superficial. No se encontraron cambios significativos en la actividad de electromiografía, variables metabólicas y de rendimiento con el uso de medias de compresión gradual en ninguna de las variables medidas durante esfuerzos de carrera submáximos.es-ES
dc.description.abstractTThe aim of this study was to evaluate changes in electromyographic activity with the use of gradual compression stockings (GCSs) on middle-distance endurance athletes’ performance, based on surface electromyography measurement techniques. Sixteen well-trained athletes were recruited (mean ± SD: age 33.4 ± 6.3 years, VO2max 63.7 ± 6.3 mL·kg−1·min−1, maximal aerobic speed 19.7 ± 1.5 km·h). The athletes were divided into two groups and were assigned in a randomized order to their respective groups according to their experience with the use of GCSs. Initially, a maximum oxygen consumption (VO2max) test was performed to standardize the athletes’ running speeds for subsequent tests. Afterward, electromyographic activity, metabolic, and performance variables for each group were measured with surface electromyography. In addition, blood lactate concentration was measured, both with and without GCSs, during 10 min at 3% above VT2 (second ventilatory threshold), all of which were performed on the track. Next, surface electromyography activity was measured during a 1 km run at maximum speed. No significant changes were found in electromyography activity, metabolic and performance variables with GCSs use (p > 0.164) in any of the variables measured. Overall, there were no performance benefits when using compression garments against a control condition.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightsCreative Commons Reconocimiento-NoComercial-SinObraDerivada Españaes_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/es_ES
dc.sourceRevista: Sensors, Periodo: 1, Volumen: 20, Número: 5, Página inicial: 1268, Página final: .es_ES
dc.titleMuscle Activation in Middle-Distance Athletes with Compression Stockings. International Journal of Sports Phys and Perfomance.es_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordsmedias de compresión gradual, electromiografía superficial, atletas de resistenciaes-ES
dc.keywordssurface electromyography; compression garment; gradual‐elastic compression stockings; muscular fatigue; endurance athletesen-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Muscle Activation in Middle Distance Athletes with Compression Stockings. Sensors (2020).pdf321,63 kBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.