Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/4874
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorSaiz Marín, Elenaes-ES
dc.contributor.authorLobato Miguélez, Enriquees-ES
dc.contributor.authorEgido Cortés, Ignacioes-ES
dc.contributor.authorGómez-Sánchez, Carmenes-ES
dc.date.accessioned2016-01-15T11:15:10Z-
dc.date.available2016-01-15T11:15:10Z-
dc.date.issued2014-11-01es_ES
dc.identifier.issn1752-1416es_ES
dc.identifier.urihttps://doi.org/10.1049/iet-rpg.2013.0308es_ES
dc.descriptionArtículos en revistases_ES
dc.description.abstractCurrent technology developments allow the provision of voltage/reactive control of wind turbines. This study focuses on the impact of wind power voltage control on both the transmission network (TNet) and the wind energy harvesting network (HNet). Different possibilities of implementing the control representative of the current situation where wind farms maintain a fixed power factor and future situation where wind farms will provide a proportional voltage control are tested. In addition, optimal controls with a certain objective function such as minimising the HNet losses or optimising the reactive power delivered to the TNet are implemented for comparison purposes. The impact of each implementation of voltage control on the HNet is assessed by means of the value of grid losses, whereas the impact on TNet is measured by the PQ capability curve and the voltage value at the bus that connects the wind energy HNet with the TNet. In addition, the importance of the transformers taps in the control is evaluated and conclusions depending on the topology of the network are obtained thanks to the analysis of two actual Spanish networks.es-ES
dc.description.abstractCurrent technology developments allow the provision of voltage/reactive control of wind turbines. This study focuses on the impact of wind power voltage control on both the transmission network (TNet) and the wind energy harvesting network (HNet). Different possibilities of implementing the control representative of the current situation where wind farms maintain a fixed power factor and future situation where wind farms will provide a proportional voltage control are tested. In addition, optimal controls with a certain objective function such as minimising the HNet losses or optimising the reactive power delivered to the TNet are implemented for comparison purposes. The impact of each implementation of voltage control on the HNet is assessed by means of the value of grid losses, whereas the impact on TNet is measured by the PQ capability curve and the voltage value at the bus that connects the wind energy HNet with the TNet. In addition, the importance of the transformers taps in the control is evaluated and conclusions depending on the topology of the network are obtained thanks to the analysis of two actual Spanish networks.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: IET Renewable Power Generation, Periodo: 1, Volumen: online, Número: 8, Página inicial: 915, Página final: 924es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleVoltage control assessment of wind energy harvesting networkses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordsvoltage control; wind turbines; optimal control; wind power; reactive power controles-ES
dc.keywordsvoltage control; wind turbines; optimal control; wind power; reactive power controlen-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IIT-14-049A.pdf1,93 MBAdobe PDFVisualizar/Abrir     Request a copy
IIT-14-049A_preview2,89 kBUnknownVisualizar/Abrir
IIT-14-049A_preview.pdf2,89 kBAdobe PDFVisualizar/Abrir