Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/4896
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorSaiz Marín, Elenaes-ES
dc.contributor.authorLobato Miguélez, Enriquees-ES
dc.contributor.authorEgido Cortés, Ignacioes-ES
dc.date.accessioned2016-01-15T11:15:25Z-
dc.date.available2016-01-15T11:15:25Z-
dc.date.issued2014-07-01es_ES
dc.identifier.issn0885-8950es_ES
dc.identifier.urihttps:doi.org10.1109TPWRS.2014.2299290es_ES
dc.descriptionArtículos en revistases_ES
dc.description.abstractes-ES
dc.description.abstractThis paper identifies when the transmission network local hosting capacity for a wind harvesting network may be limited because of steady-state bus voltage limits. In addition, the paper addresses how with the wind farm voltage control provision, such constraints may be overcome and the local hosting capacity can be increased. To answer these questions, actual Spanish system data is used on different network models of increasing complexity. Firstly, a simplified model of both transmission network and harvesting network is discussed to show that generally, only buses with low short-circuit power and low or high reactance-resistance ratio may limit local hosting capacity significantly. Secondly, in order to assess how modeling simplifications affect the results, the full model of an actual Spanish harvesting network is considered: the real reactive capability of the harvesting network at the transmission network connection node is computed and the local hosting capacity recalculated. Finally, in the last step, the results of the aforementioned simplified models are validated using the complete model of the Spanish transmission network. In addition, a complementary area hosting capacity analysis is included in order to show the importance of steady-state bus voltage constraints when large amounts of power need to be transported over long distances.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: IEEE Transactions on Power Systems, Periodo: 1, Volumen: online, Número: 4, Página inicial: 1731, Página final: 1738es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleLocal hosting capacity increase by means of wind farm voltage control provisiones_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsFlexible AC transmission systems, voltage control, wind energy.en-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IIT-14-014A.pdf1,61 MBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.