Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/5025
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorGonzález García, Alezeiaes-ES
dc.contributor.authorEchavarren Cerezo, Franciscoes-ES
dc.contributor.authorRouco Rodríguez, Luises-ES
dc.contributor.authorGómez San Román, Tomáses-ES
dc.date.accessioned2016-01-15T11:16:49Z-
dc.date.available2016-01-15T11:16:49Z-
dc.date.issued2012-08-01es_ES
dc.identifier.issn0885-8950es_ES
dc.identifier.urihttps:doi.org10.1109TPWRS.2011.2180934es_ES
dc.descriptionArtículos en revistases_ES
dc.description.abstractes-ES
dc.description.abstractDistribution networks are operated in a radial configuration, but their topology, especially in urban areas, is normally meshed in order to improve reliability of supply. This makes it possible to configure the network after a power outage to restore the service to affected customers by alternative ways of supply. Distribution operation and planning decisions usually involve network reconfiguration studies. Network reconfiguration entails changing the state of network switches to redistribute loads among feeders in order to restore service or minimize losses or alleviate overloads or voltages out of limits. The switching operation is the basic control action in network reconfiguration. A switching operation consists of closing the switch in an opened branch and opening the switch in a closed one, keeping the network configuration radial. As a consequence, the computation of sensitivities of the state variables with respect to switching operations is a useful resource for predicting the changes in a network during a reconfiguration process. This paper presents a method for computing the sensitivities of the state variables with respect to switching operations and obtaining estimations of voltages and power flows in the network. The proposed method not only provides accurate estimations, but also implies low computation load. To illustrate the performance of the developed method, a 16 bus test system and a real scenario of the 15 kV Madrid distribution system were analyzed. For both cases, the bus voltages and the feeder power flows were estimated and compared with the power flow solution. In addition, an analysis of the computation load is presented.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: IEEE Transactions on Power Systems, Periodo: 1, Volumen: online, Número: 3, Página inicial: 1294, Página final: 1301es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleA sensitivities computation method for reconfiguration of radial networkses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsdistribution networks, network reconfiguration, switching operation, sensitivity analysis.en-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IIT-12-005A.pdf1,23 MBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.