Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/5252
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorMuñíz Valencia, Robertoes-ES
dc.contributor.authorCeballos Magaña, Silvia G.es-ES
dc.contributor.authorGonzalo Lumbreras, Raqueles-ES
dc.contributor.authorSantos Montes, Ana Maríaes-ES
dc.contributor.authorIzquierdo Hornillos, Robertoes-ES
dc.date.accessioned2016-01-15T11:18:59Z-
dc.date.available2016-01-15T11:18:59Z-
dc.date.issued01/03/2008es_ES
dc.identifier.issn1615-9306es_ES
dc.identifier.urihttp://hdl.handle.net/11531/5252-
dc.descriptionArtículos en revistases_ES
dc.description.abstractes-ES
dc.description.abstractA GC-MS method for the determination of AAS used as growth promoting agents using SIM in piglet feed samples has been developed and validated, using testosterone as internal standard. The formation of volatile steroid derivatives was carried out by derivatization with N-methyl-N-(trimethylsilyl)trifluoroacetamide. The optimum separation was achieved using a Zebron ZB-5 column under a gradient temperature elution, allowing the separation of steroids in 18 min. The required sample treatment process was discussed. A leaching using ACN, saponification using a binary NaOH/MgCl2 solution, and LLE using ethyl acetate were finally selected. Method validation has been carried out according to the Commission Decision 2002/657/EC criteria established for quantitative confirmatory methods. The extraction efficiencies, CCalpha and CCbeta for these compounds were in the ranges 78-98\%, 10-21 and 18-35 mug/kg, respectively. The repeatability and the within-laboratory reproducibility at 1, 1.5, and 2 CCbeta concentration levels were smaller than 8.2, 7.5, and 5.8\% and 12.2, 9.5, and 7.5\%, respectively. Accuracy was in the 99-103\% range. The robustness was evaluated using the Youden robustness test. The proposed method was applied to the analysis of steroids spiked in different kinds of animal feed samples with satisfactory results.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: Journal of Separation Science, Periodo: 1, Volumen: 31, Número: 4, Página inicial: 727, Página final: 34es_ES
dc.titleGC-MS method development and validation for anabolic steroids in feed sampleses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsAnabolic steroids; Animal feed; Derivatization; Growth promoting agentsen-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IIT-08-086A.pdf702,14 kBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.