Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/5266
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorMuñíz Valencia, Robertoes-ES
dc.contributor.authorGonzalo Lumbreras, Raqueles-ES
dc.contributor.authorSantos Montes, Ana Maríaes-ES
dc.contributor.authorIzquierdo Hornillos, Robertoes-ES
dc.date.accessioned2016-01-15T11:19:08Z-
dc.date.available2016-01-15T11:19:08Z-
dc.date.issued01/11/2007es_ES
dc.identifier.issn1615-9306es_ES
dc.identifier.urihttp://hdl.handle.net/11531/5266-
dc.descriptionArtículos en revistases_ES
dc.description.abstractes-ES
dc.description.abstractA LC method for corticosteroids (CC) determination in poultry feed using a Chromolith column and UV detection has been developed and validated. The method development involved the optimization of different hydro-organic mobile phases using methanol or ACN as organic modifiers, flow rate, and temperature. The optimum separation was achieved at 40 degrees C using ACN/water (21:79 v/v) as mobile phase and 3 mL/min flow rate, allowing the separation to baseline of four out of seven CC in about 10 min. Prior to LC, a sample preparation procedure previously assayed for anabolics was used. It includes a leaching process, saponification of the esters from fatty acids, and SPE. Method validation was carried out according to the EU criteria established for quantitative screening methods. The extraction efficiencies, decision limits (CCalpha), and detection capabilities (CCbeta) for these compounds were in the ranges of 86-92\%, 27-36 microg/kg, and 33-43 microg/kg, respectively. The repeatability and the within-laboratory reproducibility at 1, 1.5, and 2 CCbeta concentration levels were smaller than 9.0, 5.0, and 4.2\% and 9.4, 6.4, and 4.9\%, respectively. The CV values of the robustness test were less than 3.8\% and the accuracy was in the range of 98-103\%. The proposed method was applied to other feed with satisfactory results.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: Journal of Separation Science, Periodo: 1, Volumen: 30, Número: 17, Página inicial: 2950, Página final: 7es_ES
dc.titleMethod development validation for corticoids in animal feed samples by liquid chromatography using a monolithic columnes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsAnimal feed; Corticoids; Monolithic columnen-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IIT-07-059A.pdf803,93 kBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.