Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/5279
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorGonzalo Lumbreras, Raqueles-ES
dc.contributor.authorMuñíz Valencia, Robertoes-ES
dc.contributor.authorSantos Montes, Ana Maríaes-ES
dc.contributor.authorIzquierdo Hornillos, Robertoes-ES
dc.date.accessioned2016-01-15T11:19:14Z-
dc.date.available2016-01-15T11:19:14Z-
dc.date.issued01/07/2007es_ES
dc.identifier.issn0021-9673es_ES
dc.identifier.urihttp://hdl.handle.net/11531/5279-
dc.descriptionArtículos en revistases_ES
dc.description.abstractes-ES
dc.description.abstractA LC isocratic separation study of a complex mixture containing 18 steroids (corticoids and anabolics), used potentially as growth promoters, was carried out. For this purpose, using a Hypersil ODS column at controlled temperature, mobile phases (from binary to quaternary) prepared from water and MeOH, ACN or THF as organic modifiers and UV detection at 245 nm, were employed (dehydroepiandrosterone was detected at 200 nm). The optimum separation was achieved using water/acetonitrile (65:35, v/v) as mobile phase at 30 degrees C, allowing the separation of 16 out of 18 steroids in about 30 min. The retention scale using optimized binary mobile phases was related with steroids hydrophobicity and structure, allowing a classification into three groups for these compounds. To improve the separation several alkyl-silica packings were tested: Type A (Lichrospher C8) and Type B (Luna C18, Kromasil C18, Purospher C18 and Synergy C12). Taking into account resolution, number of separated compounds and run time analysis the Hypersil column was selected as the best choice for further applications. Calibration graphs were obtained using fluorocortisone, fluoxymesterone or methylprednisolone as internal standard. The optimized separation was applied to the analysis of piglet feed samples spiked with steroids. The sample preparation process included solvent extraction using diethyleter and solid phase extraction using silica cartridges. The recoveries were in the range 70-92\%. Decision limits and detection capability were in the range 34-198 and 41-249 microg/kg, respectively. Repeatability was also evaluated.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: Journal of Chromatography A, Periodo: 1, Volumen: 1156, Número: 1-2, Página inicial: 321, Página final: 30es_ES
dc.titleLiquid chromatographic method development for steroids determination (corticoids and anabolics). Application to animal feed sampleses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsSteroids; Reversed-phase columns; Animal feeden-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IIT-07-058A.pdf370,72 kBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.