Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/5286
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Cledera Castro, Mª del Mar | es-ES |
dc.contributor.author | Santos Montes, Ana María | es-ES |
dc.contributor.author | Izquierdo Hornillos, Roberto | es-ES |
dc.contributor.author | Gonzalo Lumbreras, Raquel | es-ES |
dc.date.accessioned | 2016-01-15T11:19:18Z | - |
dc.date.available | 2016-01-15T11:19:18Z | - |
dc.date.issued | 01/03/2007 | es_ES |
dc.identifier.issn | 1615-9306 | es_ES |
dc.identifier.uri | http://hdl.handle.net/11531/5286 | |
dc.description | Artículos en revistas | es_ES |
dc.description.abstract | es-ES | |
dc.description.abstract | A systematic optimization of the HPLC separation of a mixture containing 11 pollu- tant phenols (PPs) using a Hypersil ODS (250mm64.6 mm, 5 lm) column and UV- DAD detection has been carried out. The binary mobile phases used were obtained by mixing 50mM phosphate (pH = 3.0) and methanol, ACN, or THF as organic modi- fiers. After selecting ACN as an organic modifier, the effects of pH and temperature on PPs separation were studied. A mobile phase of 50mM acetate (pH = 5.0)-ACN (60:40 v/v) at 508C allowed the separation of 11 phenols but not to baseline in 17 min. To improve the performance of this separation, the following RP columns were tested: Luna C18 (2), Purospher C18, Synergi C12, Synergi Fusion C18, Gemini C18, Luna Cyano, Lichrospher C8, and Envirosep-PP (polymeric). In all the cases, the performance (analysis time, retention, selectivity, resolution, asymmetry factors, and efficiency) was evaluated. A further reoptimization of the mobile phase was car- ried out for all the columns by studying the ACN content and pH, with the aim of improving the above-mentioned separations and selecting the most suitable one for PPs analysis. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | en-GB | es_ES |
dc.rights | es_ES | |
dc.rights.uri | es_ES | |
dc.source | Revista: Journal of Separation Science, Periodo: 1, Volumen: 30, Número: 5, Página inicial: 699, Página final: 707 | es_ES |
dc.subject.other | Instituto de Investigación Tecnológica (IIT) | es_ES |
dc.title | Comparison of the performance of different reversed-phase columns for liquid chromatography separation of 11 pollutant phenols | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.description.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/restrictedAccess | es_ES |
dc.keywords | es-ES | |
dc.keywords | Pollutant phenols / Reversed-phase columns | en-GB |
dc.identifier.doi | 10.1002/jssc.200600301 | es_ES |
Aparece en las colecciones: | Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
IIT-07-057A.pdf | 594,83 kB | Adobe PDF | Visualizar/Abrir Request a copy |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.