Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/5286
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorCledera Castro, Mª del Mares-ES
dc.contributor.authorSantos Montes, Ana Maríaes-ES
dc.contributor.authorIzquierdo Hornillos, Robertoes-ES
dc.contributor.authorGonzalo Lumbreras, Raqueles-ES
dc.date.accessioned2016-01-15T11:19:18Z-
dc.date.available2016-01-15T11:19:18Z-
dc.date.issued01/03/2007es_ES
dc.identifier.issn1615-9306es_ES
dc.identifier.urihttp://hdl.handle.net/11531/5286
dc.descriptionArtículos en revistases_ES
dc.description.abstractes-ES
dc.description.abstractA systematic optimization of the HPLC separation of a mixture containing 11 pollu- tant phenols (PPs) using a Hypersil ODS (250mm64.6 mm, 5 lm) column and UV- DAD detection has been carried out. The binary mobile phases used were obtained by mixing 50mM phosphate (pH = 3.0) and methanol, ACN, or THF as organic modi- fiers. After selecting ACN as an organic modifier, the effects of pH and temperature on PPs separation were studied. A mobile phase of 50mM acetate (pH = 5.0)-ACN (60:40 v/v) at 508C allowed the separation of 11 phenols but not to baseline in 17 min. To improve the performance of this separation, the following RP columns were tested: Luna C18 (2), Purospher C18, Synergi C12, Synergi Fusion C18, Gemini C18, Luna Cyano, Lichrospher C8, and Envirosep-PP (polymeric). In all the cases, the performance (analysis time, retention, selectivity, resolution, asymmetry factors, and efficiency) was evaluated. A further reoptimization of the mobile phase was car- ried out for all the columns by studying the ACN content and pH, with the aim of improving the above-mentioned separations and selecting the most suitable one for PPs analysis.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: Journal of Separation Science, Periodo: 1, Volumen: 30, Número: 5, Página inicial: 699, Página final: 707es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleComparison of the performance of different reversed-phase columns for liquid chromatography separation of 11 pollutant phenolses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsPollutant phenols / Reversed-phase columnsen-GB
dc.identifier.doi10.1002/jssc.200600301es_ES
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IIT-07-057A.pdf594,83 kBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.