Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/5295
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | López-Silva, Sonnia María | es-ES |
dc.contributor.author | Silveira Martín, Juan Pedro | es-ES |
dc.contributor.author | Dotor Castilla, María Luisa | es-ES |
dc.contributor.author | Giannetti, Romano | es-ES |
dc.contributor.author | Golmayo Fernández, Dolores | es-ES |
dc.contributor.author | Herrera Noreña, Luis Antonio | es-ES |
dc.date.accessioned | 2016-01-15T11:19:23Z | - |
dc.date.available | 2016-01-15T11:19:23Z | - |
dc.date.issued | 2006-10-01 | es_ES |
dc.identifier.issn | 0967-3334 | es_ES |
dc.identifier.uri | https:doi.org10.10880967-33342710009 | es_ES |
dc.description | Artículos en revistas | es_ES |
dc.description.abstract | es-ES | |
dc.description.abstract | Photoplethysmography and pulse oximetry are techniques based on optical principles, which are widely used in medical practice for non-invasive monitoring. There are some processes which may affect specific organs or parts without a significant repercussion on the information provided non-invasively. Here, we report on the preliminary results obtained by transmittance photoplethysmography in pig intra-peritoneal organs along a surgical intervention, using a measurement system based on two near-infrared laser diodes. Analysis of the signals recorded at 750 nm and 850 nm in the mesentery root, mesocolon, gastric wall and aorta artery has shown the affordability of performing in situ photoplethysmography for visceral perfusion evaluation. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | en-GB | es_ES |
dc.rights | es_ES | |
dc.rights.uri | es_ES | |
dc.source | Revista: Physiological Measurement, Periodo: 1, Volumen: online, Número: 10, Página inicial: 1033, Página final: 1045 | es_ES |
dc.subject.other | Instituto de Investigación Tecnológica (IIT) | es_ES |
dc.title | Transmittance photoplethysmography with near-infrared laser diodes in intra-peritoneal organs | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.description.version | info:eu-repo/semantics/publishedVersion | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/restrictedAccess | es_ES |
dc.keywords | es-ES | |
dc.keywords | Laser diodes, optical sensor, photoplethysmography, viscera | en-GB |
Aparece en las colecciones: | Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
IIT-06-073A.pdf | 1,01 MB | Adobe PDF | Visualizar/Abrir Request a copy |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.