Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/5345
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorGarcía Cerrada, Aurelioes-ES
dc.contributor.authorRoncero Sánchez-Elipe, Pedro Luises-ES
dc.contributor.authorGarcía González, Pabloes-ES
dc.contributor.authorFeliú Batlle, Vicentees-ES
dc.date.accessioned2016-01-15T11:19:50Z-
dc.date.available2016-01-15T11:19:50Z-
dc.date.issued2004-11-01es_ES
dc.identifier.issn1350-2352es_ES
dc.identifier.urihttps://doi.org/10.1049/ip-epa:20040804es_ES
dc.descriptionArtículos en revistases_ES
dc.description.abstractThis paper investigates the design and application of selective controllers for voltage-source-inverter output control. These controllers can be applied to minimise the effects of the inverter dead times on output-voltage harmonics or to provide flexible control of the inverter low-frequency output-voltage harmonics. The paper investigates the closed-loop stability of the resulting systems thoroughly and explains the controller design process from the frequency-response viewpoint. It is clearly demonstrated that a compromise has to be reached between transient-response speed and tracking (or rejection) accuracy. The main contributions of the paper are illustrated with a prototype where the two applications proposed for this type of controllers are tested.es-ES
dc.description.abstractThis paper investigates the design and application of selective controllers for voltage-source-inverter output control. These controllers can be applied to minimise the effects of the inverter dead times on output-voltage harmonics or to provide flexible control of the inverter low-frequency output-voltage harmonics. The paper investigates the closed-loop stability of the resulting systems thoroughly and explains the controller design process from the frequency-response viewpoint. It is clearly demonstrated that a compromise has to be reached between transient-response speed and tracking (or rejection) accuracy. The main contributions of the paper are illustrated with a prototype where the two applications proposed for this type of controllers are tested.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: IEE Proceedings-Electric Power Applications, Periodo: 1, Volumen: online, Número: 6, Página inicial: 734, Página final: 743es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleDetailed analysis of closed-loop control of output-voltage harmonics in voltage-source inverterses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordsVoltage-source inverters, selective harmonic elimination, closed-loop control, inverter output voltagees-ES
dc.keywordsVoltage-source inverters, selective harmonic elimination, closed-loop control, inverter output voltageen-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IIT-03-004A.pdf652,38 kBAdobe PDFVisualizar/Abrir     Request a copy
IIT-03-004A_preview2,65 kBUnknownVisualizar/Abrir
IIT-03-004A_preview.pdf2,65 kBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.