Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/5345Registro completo de metadatos
| Campo DC | Valor | Lengua/Idioma |
|---|---|---|
| dc.contributor.author | García Cerrada, Aurelio | es-ES |
| dc.contributor.author | Roncero Sánchez-Elipe, Pedro Luis | es-ES |
| dc.contributor.author | García González, Pablo | es-ES |
| dc.contributor.author | Feliú Batlle, Vicente | es-ES |
| dc.date.accessioned | 2016-01-15T11:19:50Z | - |
| dc.date.available | 2016-01-15T11:19:50Z | - |
| dc.date.issued | 2004-11-01 | es_ES |
| dc.identifier.issn | 1350-2352 | es_ES |
| dc.identifier.uri | https://doi.org/10.1049/ip-epa:20040804 | es_ES |
| dc.description | Artículos en revistas | es_ES |
| dc.description.abstract | This paper investigates the design and application of selective controllers for voltage-source-inverter output control. These controllers can be applied to minimise the effects of the inverter dead times on output-voltage harmonics or to provide flexible control of the inverter low-frequency output-voltage harmonics. The paper investigates the closed-loop stability of the resulting systems thoroughly and explains the controller design process from the frequency-response viewpoint. It is clearly demonstrated that a compromise has to be reached between transient-response speed and tracking (or rejection) accuracy. The main contributions of the paper are illustrated with a prototype where the two applications proposed for this type of controllers are tested. | es-ES |
| dc.description.abstract | This paper investigates the design and application of selective controllers for voltage-source-inverter output control. These controllers can be applied to minimise the effects of the inverter dead times on output-voltage harmonics or to provide flexible control of the inverter low-frequency output-voltage harmonics. The paper investigates the closed-loop stability of the resulting systems thoroughly and explains the controller design process from the frequency-response viewpoint. It is clearly demonstrated that a compromise has to be reached between transient-response speed and tracking (or rejection) accuracy. The main contributions of the paper are illustrated with a prototype where the two applications proposed for this type of controllers are tested. | en-GB |
| dc.format.mimetype | application/pdf | es_ES |
| dc.language.iso | en-GB | es_ES |
| dc.rights | es_ES | |
| dc.rights.uri | es_ES | |
| dc.source | Revista: IEE Proceedings-Electric Power Applications, Periodo: 1, Volumen: online, Número: 6, Página inicial: 734, Página final: 743 | es_ES |
| dc.subject.other | Instituto de Investigación Tecnológica (IIT) | es_ES |
| dc.title | Detailed analysis of closed-loop control of output-voltage harmonics in voltage-source inverters | es_ES |
| dc.type | info:eu-repo/semantics/article | es_ES |
| dc.description.version | info:eu-repo/semantics/publishedVersion | es_ES |
| dc.rights.holder | es_ES | |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
| dc.keywords | Voltage-source inverters, selective harmonic elimination, closed-loop control, inverter output voltage | es-ES |
| dc.keywords | Voltage-source inverters, selective harmonic elimination, closed-loop control, inverter output voltage | en-GB |
| Aparece en las colecciones: | Artículos | |
Ficheros en este ítem:
| Fichero | Descripción | Tamaño | Formato | |
|---|---|---|---|---|
| IIT-03-004A.pdf | 652,38 kB | Adobe PDF | Visualizar/Abrir Request a copy | |
| IIT-03-004A_preview | 2,65 kB | Unknown | Visualizar/Abrir | |
| IIT-03-004A_preview.pdf | 2,65 kB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.