Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/56060
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorZhang, Qianes-ES
dc.contributor.authorMcCalley, James D.es-ES
dc.contributor.authorAjjarapu, Venkataramanaes-ES
dc.contributor.authorRenedo Anglada, Javieres-ES
dc.contributor.authorElizondo, Marcelo A.es-ES
dc.contributor.authorTbaileh, Ahmades-ES
dc.contributor.authorMohan, Nihales-ES
dc.date.accessioned2021-06-07T11:50:18Z-
dc.date.available2021-06-07T11:50:18Z-
dc.date.issued2021-01-01es_ES
dc.identifier.issn0885-8950es_ES
dc.identifier.urihttps:doi.org10.1109TPWRS.2020.3013638es_ES
dc.descriptionArtículos en revistases_ES
dc.description.abstractes-ES
dc.description.abstractThis paper proposes a frequency control strategy for voltage source converter based multi-terminal HVDC systems (VSC-MTDC) to facilitate the exchange of primary frequency reserves among asynchronous AC systems, thus providing frequency support from each AC system to the others. The proposed frequency control utilizes a reference signal calculated from global measurements which reflects the overall frequency dynamics of all connected asynchronous AC systems. The proposed control outperforms the traditional frequency droop scheme by reducing impact on the DC voltage profile and improving frequency nadir. The performance of the designed frequency control with different DC voltage droop controls is evaluated. The adaptation of the proposed frequency control for converter outages is analyzed. The robustness of the proposed control to communication latency and the sensitivity of frequency support to power limits are also investigated. The VSCMTDC model and the proposed control are implemented in the commercial grade software PSSE and thus is suitable to study large-scale realistic systems and can be incorporated into the power system planning process at utilities and ISOs. The effectiveness of the proposed control is illustrated on a developed AC-MTDC test system and also on a large-scale realistic model combining the North American Western Interconnection (WI) and Eastern Interconnection (EI) with continental HVDC interconnections.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: IEEE Transactions on Power Systems, Periodo: 1, Volumen: online, Número: 1, Página inicial: 806, Página final: 817es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titlePrimary frequency support through North American continental HVDC interconnections with VSC-MTDC systemses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsVSC-MTDC, frequency support, droop control, PSSEen-GB
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IIT-20-088A.pdf4,21 MBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.