Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/5609
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorLópez-Silva, Sonnia Maríaes-ES
dc.contributor.authorDotor Castilla, María Luisaes-ES
dc.contributor.authorSilveira, J.es-ES
dc.contributor.authorGiannetti, Romanoes-ES
dc.contributor.authorMiguel-Tobal, Franciscoes-ES
dc.contributor.authorBilbao Monasterio, Amayaes-ES
dc.contributor.authorGalindo Canales, Mercedeses-ES
dc.contributor.authorMartín Escudero, Pilares-ES
dc.date.accessioned2016-01-15T11:27:24Z-
dc.date.available2016-01-15T11:27:24Z-
dc.date.issued2010-05-03es_ES
dc.identifier.urihttp://hdl.handle.net/11531/5609-
dc.descriptionCapítulos en libroses_ES
dc.description.abstractes-ES
dc.description.abstractPhotoplethysmography (PPG) is a non-invasive optical technique that enables to quantify the arterial blood pulse rate derived from the cardiac pumping action. Although this technique is widely used in the medical practice as part of pulse oximeters, the signal corruption by motion artifacts is a primary limitation in the practical accuracy and applicability of current instruments to monitor pulse rate during intense exercise. Here, we report on the application of transmittance PPG throughout maximal exercise tests in cycle ergometer in male athletes. A specifically developed algorithm has been applied to obtain PPG pulse rates similar to the reference heart rates.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.publisherIEEE (Austin, Estados Unidos de América)es_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceLibro: IEEE International Instrumentation and Measurement Technology Conference, I2MTC'2010, Página inicial: 1039-1043, Página final:es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titlePulse rate measurement from transmittance photoplethysmography in cycle ergometer testes_ES
dc.typeinfo:eu-repo/semantics/bookPartes_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsPhotoplethysmography, motion artifact, heart rate, pulse rate, non-invasive measurement, cycle testen-GB